What does no Enc mean?
The carriage has been moved too fast, or
The sensor and the readout are not communicating.
To clear this error:
1. Be sure the moving carriage is on the electronic scale.
2. Unplug the encoder from the readout for five seconds.
3. Connect the encoder to the readout.
What does b FAIL mean?
When the readout displays this message, it means the battery voltage
has dropped to a level where reliable operation is no longer possible.
Install a new battery to clear this message.
What does P FAIL mean?
When the readout displays this message, it means the battery voltage
has dropped to a level where reliable programming is not possible.
Install a new battery to clear this message.
The readout does not change, or changes very little, as it moves.
1. The readout is in the HOLD mode.
2. The linear scaling factor is set very low.
The r
eadout alternately shows “no Co” and a measurement.
The readout has non-linear compensation enabled, and:
1.
The position of the encoder is outside the calibrated range.
Move the encoder to a position within the calibrated range
2. The system
’s datum has changed.
Place the moving carriage against the fixed jaw, then press
DATUM key.
3. The readout is in INC mode.
Return to ABS mode and verify system is datumed
.