15
Note:
The power adaptor is intended to be correctly oriented in a vertical or floor mounted position. The
prongs are not designed to hold the plug in place if it is plugged into a ceiling, under-table or cabinet outlet.
Figure 12
Note:
If the power adaptor is plugged in,
BL ON
will display in the time area for three seconds when
powered up. Conversely, if the power adaptor is not plugged in,
AC OFF
will be displayed, the icon
will
display.
Sensor Operation Verification
The following steps verify proper operation of the sensors prior to installing the sensor array.
1. Verify proper operation of the rain gauge.
Tip the sensor array back and forth several times. You should
hear a “clicking” sound within the rain gauge. Verify the rain reading on the display console is not reading
0.00. Each “click” represents 0.3mm of rainfall.
2. Verify proper operation of the wind speed sensor.
Rotate the wind cups manually or with a constant
speed fan. Verify the wind speed is not reading 0.0.
3. Verify proper operation of the indoor and outdoor temperature sensors.
Verify the indoor and outdoor
temperature readings match closely with the console and sensor array in the same location (about 3m apart).
The sensors should be within 2°C (the accuracy is ±1°C). Allow about 30 minutes for both sensors to stabilise.
4. Verify proper operation of the indoor and outdoor humidity sensors.
Verify the indoor and outdoor
humidity readings match closely with the console and sensor array in the same location (about 3m apart). The
sensors should be within 10% (the accuracy is ± 5%). Allow about 30 minutes for both sensors to stabilise.