Time of use(TOU) energy
Table 5-17 TOU Energy Address
Modbus address
Parameter description Data
type
R/W
Data range
Default Model Register
number
HEX
Decimal
TOU Parameter
400H
1024
Wrong Parameter
Setting 1
See Appendix
“Tariff
Parameter
Wrong
Information 1”
2~4
1
401H
1025
Wrong Parameter
Setting 2
See Appendix
“Tariff
Parameter
Wrong
Information 1”
2~4
1
402H
1026
Time Zone Selecting Word R/W
1-14
1
2~4
1
403H
1027
Schedule Setting:
number of schedules
to configure
Word R/W
1-8
2
2~4
1
404H
1028
Segment Setting:
number of time
segments per
schedule
Word R/W
1-14
2
2~4
1
405H
1029
Tariff: number of
tariffs to configure
Word R/W
1-4
4
2~4
1
406H
1030
Weekend Setting:
Word R/W
Bit0-bit6
1: weekdays;
0: weekends
0
2~4
1
407H
1031
Weekend Schedule
Word R/W
1-8
1
2~4
1
408H
1032
Number of Holidays Word R/W
0-30
0
2~4
1
409H
1033
TOU auto reset fixed
date: day (default is 1) Word R/W
1-28
1
2~4
1