background image

AT2T-3238-1 Rev. C

ACCU-STEAM

GAS GRIDDLE OWNERS MANUAL

Page

15/29

SERVICE AND TROUBLESHOOTING (cont.)

Heat light will not come on



Make sure the griddle is not hotter than the temperature you have it set for.

If you have turned down the temperature of the griddle, the heat light will
not come on again until the cooking surface drops below the temperature you
have set.



See if the heat light is coming on intermittently. While operating in a normal

condition, the heat light cycles on and off periodically when at temperature.



Call the AccuTemp Products, Inc Technical & Customer Support Department
at +1-260-469-3040 or toll free at 1-800-480-0415.

Uneven or inaccurate surface temperatures



Verify the surface temperature with an accurate surface probe thermometer.

Use of an infrared thermometer will not give an accurate reading of
the griddle surface temperatures.



Call the AccuTemp Products, Inc Technical & Customer Support Department
at +1-260-469-3040 or toll free at 1-800-480-0415.

Unit will not turn off



This indicates a serious control malfunction.



Turn off the griddle’s electrical supply at the source.



Call the AccuTemp Products, Inc Technical & Customer Support Department

at +1-260-469-3040 or toll free at 1-800-480-0415.

NOTE

An AccuTemp Products, Inc. Technical & Customer Support Technician is

available Monday thru Sunday, 7:00am to 7:00pm EST.

+1-260-469-3040 or 1-800-480-0415

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Summary of Contents for AT0H-3035

Page 1: ...hn F mi Fw SrI N tpU I VeI4o yo twiuc1 wirlanty E8S9 1O tent YJ b as IM M i FW e t fl kil LP 1 ft t c k u1 M tIomn ACCU STEAM GAS GRIDDLE OWNERS MANUAL IMPORTANT WARRANTY INFORMATION For product warra...

Page 2: ...is Manual for future reference WARNING In the event a gas odor is detected shut down all appliances at the main gas shut off valve and contact the local gas company or gas supplier for service WARNING...

Page 3: ...warning information Page 7 Modified Electrical Requirements section Pages 8 9 Modified Gas Connection section Page 10 Revised reference for Product Registration Form Page 12 Added second supplier for...

Page 4: ...AND BTU CONTENT 17 GAS GRIDDLE ASSEMBLY SERVICE PARTS 18 19 COMBUSTION CHAMBER ASSEMBLY SERVICE PARTS 20 22 PILOT BURNER ASSEMBLY SERVICE PARTS 23 GAS CONTROL VALVE ASSEMBLY SERVICE PARTS 24 CONTROL P...

Page 5: ...XT BOXES Below are definitions of the warning text boxes DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially...

Page 6: ...his manual ALERT Notifies the reader of an important message warning usually a safety related message INFORMATION Notifies the reader of important information that may or may not be safety related EAR...

Page 7: ...n turning food in place AT2T 3238 1 Rev C ACCL S TEA MTM GAS GRIDDLE OWNERS MANUAL Page 3 29 Stii1ee Ste1 Cocku q ui face Stan1 Se Reiriorcirig 5I iE ___ AT2T 3238 1 Rev C ACCU STEAM GAS GRIDDLE OWNER...

Page 8: ...STEAM gas griddle can be placed on a commercial kitchen counter top or AccuTemp griddle stand The operating temperature ranges from 200 400 F 93 204 C Since these temperatures can also be found on sur...

Page 9: ...to ensure it is level front to back and left to right If this is a counter top installation the griddle must be set and leveled using the adjusters on the legs before installing the 4 rubber foot tips...

Page 10: ...meet or exceed the demanding standards of safety set forth by Underwriters Laboratories Inc To ensure that this high level of safety is maintained in your installation it is important that you read a...

Page 11: ...to ensure it is level front to back and left to right If this is a counter top installation the griddle must be set and leveled using the adjusters on the legs before installing the 4 rubber foot tips...

Page 12: ...t flue will cause plug and cord failures that will not be covered under the warranty It is recommended that the wall receptacle be positioned as low as State and local codes will allow GROUNDING INSTR...

Page 13: ...s for properly sizing the supply manifold and regulator Note Flexible residential appliance connection hoses are not suitable for this appliance and may void the warranty If your griddle installation...

Page 14: ...ompound or sealant designed for use with liquid petroleum gas when replacing the 1 8 NPT plug or the 1 4 NPT plug NOTE Do not use an excessive amount of sealant in order to prevent potential obstructi...

Page 15: ...ed at the end of this manual for reference or use as the master form to be completed during installation and later submitted to AccuTemp It is recommended that a copy of the completed ACCU STEAM Gridd...

Page 16: ...ean your griddle periodically or on a schedule you may need to repeat this process after the use of chemicals PREHEATING Turn On switch to the On position and set the thermostat to the desired tempera...

Page 17: ...220 F and 240 F 104 F and 116 C Use water ice and or griddle cleaner as needed For example the 3M Scotch Brite Quick Clean Griddle System or Ecolab Grease Express High Temp Grill Cleaner System are co...

Page 18: ...eld modification made without written authorization from AccuTemp will void the warranty WARNING Only qualified service technicians electricians should perform the installation to ensure that all elec...

Page 19: ...Call the AccuTemp Products Inc Technical Customer Support Department at 1 260 469 3040 or toll free at 1 800 480 0415 WARNING Use of any replacement parts other than those supplied by AccuTemp Product...

Page 20: ...415 Uneven or inaccurate surface temperatures Verify the surface temperature with an accurate surface probe thermometer Use of an infrared thermometer will not give an accurate reading of the griddle...

Page 21: ...le 1 2 Sheet 1 of 1 C Title Rev Drawing No Size AT0H 3035 GAS APPLIANCE STD CONVERSION KIT AccuTemp Products Inc 8415 N Clinton Park Fort Wayne IN 46825 Name Date 1 03 04 Drawn Checked 1 13 05 Project...

Page 22: ...53 8 000 63 73 51 3 64 44 53 45 53 9 000 64 73 51 56 45 53 47 54 10 000 65 74 52 57 46 54 48 55 HEAT VALUE BTU CU FT NATURAL GAS 1100 PROPANE GAS 2400 Altitude ft NG LP NG LP NG LP NG LP 0 3 999 59 70...

Page 23: ...OWER CORD 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 AT0E 2885 2 18 SENSOR REPLACEABLE 2 2 2 2 AT0B 2888 54 17 ORIFICE 3 3 3 3 AT0B 2888 52 17 ORIFICE 2 2 2 2 AT0B 2888 51 17 ORIFICE 2 2 2 2 AT0B...

Page 24: ...OR NATURAL GAS 10 W C FOR PROPANE LOCATED IN ITEM 7 2 ADJUST PILOT REGULATOR TO 3 5 W C FOR NATURAL GAS 8 W C FOR PROPANE LOCATED IN ITEM 7 C C 34 SEE NOTE 2 SEE NOTE 1 C C C 42 D 40 F G G 36 27 34 6...

Page 25: ...MPRESSION 1 1 1 AT0B 2890 1 5 ORIFICE ADAPTER 3 2 AT2B 2099 1 4 30 000 BTU IR MAIN BURNER 2 AT2B 2131 1 3 20 000 BTU IR MAIN BURNER 1 AT2M 2795 4 2 BARRIER FLUE GAS 1 AT2M 2795 3 2 BARRIER FLUE GAS 1...

Page 26: ...C 25 D EDR 045F Scale 1 3 Sheet 2 of 3 D Title Rev Drawing No Size AT2A 2818 D COMBUSTION CHAMBER ASSEMBLY AccuTemp Products Inc 8415 N Clinton Park Fort Wayne IN 46825 Name Date Drawn Checked Projec...

Page 27: ...8 7 4 20 24 C 25 D EDR 045F Scale 1 3 Sheet 3 of 3 D Title Rev Drawing No Size AT2A 2818 D COMBUSTION CHAMBER ASSEMBLY AccuTemp Products Inc 8415 N Clinton Park Fort Wayne IN 46825 Name Date Drawn Che...

Page 28: ...299 H CHG D RH VIEW 08 MAX W AS 06 MAX ADDED DETAIL B 07 10 09 21 06 LEC ATP REVISIONS E C N R E V D E S C R I P T I O N D A T E A P P R A C H G D 1 5 0 0 5 0 W A S 1 2 5 0 1 5 0 1 5 0 2 0 W A S 0 1...

Page 29: ...RON PIPE 1 1 AT0P 3024 2 5 PLUG COUNTERSUNK HEX HEAD 1 1 AT2M 2838 1 4 BRKT GAS REGULATOR 1 1 AT0P 2096 2 3 ELBOW 90 COMPRESSION 2 2 AT0P 2091 4 2 CLOSE NIPPLE PIPE 1 1 AT0P 2089 4 1 ELBOW STREET 90 E...

Page 30: ...T0E 3339 1 11 MOUNTING LATCH 2 2 2 2 2 2 AT0E 3338 1 10 CONTACT BLOCK 1 1 1 1 1 1 AT0E 3336 1 9 OPERATOR AB ROTARY SWITCH 1 1 1 1 1 1 AT2E 1807 1 8 IGNITION CONTROLLER 1 1 1 AT2L 2715 2 7 OVERLAY CONT...

Page 31: ...SAME AS AT2A 2819 1 F 21 USE THIS WELD STUD FOR AT0A 3506 1 GROUND CONNECTION K ECN Scale 1 2 Sheet 2 of 3 D Title Rev Drawing No Size K CONTROL PANEL AccuTemp Products Inc 8415 N Clinton Park Fort W...

Page 32: ...E 2 2 AT0F 1052 51002 9 WASHER 1 4 TYPE B PLAIN 2 2 AT0F 2691 21002 8 NUT 6 32 NYLOC 1 1 AT2M 2860 1 7 SOLDER WASHER 1 1 AT2F 1367 1 6 WASHER TYPE A 1 1 AT2E 1639 1 5 MICROSWITCH 1 1 AT0E 1759 1 4 MIC...

Page 33: ...ED RED ORN ORN or YEL GRN GRN BURNER 1 2 3 4 5 6 24V SEC 120V PRI MAIN GAS CONTROL VALVE MAIN BURNER VALVE SPARK MODULE HV IGNITOR SENSOR VIO AT2T 3041 DELAY TIMER BLK BLK VIO YEL BLU PDF compression...

Page 34: ...ent This warranty includes travel time not to exceed two hours and mileage not to exceed 50 miles 100 miles round trip but does not include post start up assistance or training tightening of loose fit...

Page 35: ...X X 6 Inspect the control compartment for foreign particulate and any loose wiring or connections X X 7 Daily inspect the flue for foreign particulate that has fallen inside Remove any particulate Con...

Page 36: ...an this replace transformer X X FS 3805 0804 Page 2 of 4 FS 3805 0804 Page 2 of 4 PM TASK DESCRIPTIONS DAILY ITEMS BI ANNUAL ITEMS ANNUAL ITEMS 10 Inspect the burner venturi tubes for foreign particle...

Page 37: ...the pilot burner pressure regulator and install NPT barbed hose fitting Tighten and mount the other length of the rubber hose 4 Allow the griddle to heat up to at least 200 F First check the main burn...

Page 38: ...r Reading should be above 30 millivolts Orifices and Burner Venturi Pilot and main burner orifices can collect dust and grease over time in any kitchen environment If this material blocks the orifices...

Page 39: ...for the pilot and main burners If this is a table top installation have the 4 rubber foot tips been installed circle one Yes No Is the griddle level circle one Yes No Is the grease pan installed circl...