![Accu-Sort AXIOM 400 Product Manual Download Page 65](http://html1.mh-extra.com/html/accu-sort/axiom-400/axiom-400_product-manual_3730780065.webp)
AXIOM™ 400 Product Manual
Setup and Operations
5-5
05-AXIOM400-Setup_and_Operations_R10.doc
Accu-Sort Systems, inc.
Table 5-2:
Network LED during Normal Operations
Mode Description
Single TCP/IP
Solid
GREEN
– Axiom connected to a host.
NOTE
: If both Host 1 and Host 2 are used, the LED will be solid
GREEN
if either port is connected.
Off – No host connection.
NOTE
: If UDP messaging is used (unconnected messages) the
Network LED will be off.
EtherNet/IP
Solid
GREEN
– Axiom made a connection to the PLC
Flashing
GREEN
– No connection made with the network
Flashing
RED
– Lost network connection
Controller/Client
Controller
Solid
GREEN
– The correct number of client(s) with the same
group number have been found.
Flashing
RED
– All the client(s) with the same group number
have NOT been found
Client
Solid
GREEN
– Connected to a controller with the same group
number.
Off – Not connected to a controller with the same group
number.
NOTE:
The mode indicated by the Network LED is dependent on the Axiom
configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode
operation is the lowest.
Table 5-3:
Using Control Panel Buttons to Check Normal Operations
Ref Button
Description
A
Upload to Axiom
Uploads parameters from Wiring Base to Scan Head
Button must be pressed twice to initiate action.
The bar graph LEDs flash when pressed once.
The bar graph LEDs strobe from 1 to 5 when pressed
the second time, indicating the parameters are being
uploaded from the wiring base to scan head.
B
Backup to Base
Downloads parameters from Scan Head to Wiring Base
Button must be pressed twice to initiate action.
The bar graph LEDs flash when pressed once.
The bar graph LEDs strobe from 5 to 1 when pressed
the second time, indicating the parameters are being
backed up from the scan head to the wiring base.
C
Test /Diagnostic
Enables the Axiom test mode.
(Test mode can also be selected remotely using Axcess
Tools > Axiom Commands > Test Mode
.)
REMEMBER
:
Axiom’s control panel buttons can be enabled/disabled through
the use of the Axcess setup software.
(Reference Axcess Software Manual. See
Modify > Axiom Configuration, Enable Axiom Control Panel Buttons.)
Summary of Contents for AXIOM 400
Page 1: ...AXIOM 400 Bar Code Scanning Solutions Product Manual...
Page 96: ...8 8 Service AXIOM 400 Product Manual Accu Sort Systems inc 08 AXIOM400 Service_R10 doc Notes...
Page 104: ...B 2 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 105: ...AXIOM 400 Product Manual Read Charts B 3 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...
Page 106: ...B 4 Read Charts AXIOM 400 Product Manual Accu Sort Systems inc A2 AXIOM400 ReadCharts_R10 doc...
Page 107: ...AXIOM 400 Product Manual Read Charts B 5 A2 AXIOM400 ReadCharts_R10 doc Accu Sort Systems inc...