Attach tubing to barbed fitting, secure with clamp.
9:
Lay tubing beside column pipe. Cut off 1-3 inches (25-76 mm) above the
discharge head.
10: Secure tube to column pipe with tie straps. Locate tie straps approximately 6 inches
(152 mm) from packer, 6 inches (152 mm) from discharge head and middle of tubing.
For fixed length pump, skip to conduit box wiring
11: Remove cover from wiring compartment.
12: Pull pigtail wires into wiring compartment.
13: Cut pigtail wires extending approximately 8-inches (200 mm) out of
wiring compartment.
14: Strip back insulation of all wires 3/8-inch (10 mm).
15: Using supplied wire nuts, attach like colored pump pigtail wires to wires.
See figure 4.8 to verify connections.
16: Install excess wire into wiring compartment. Replace wiring compartment cover.
Torque to 35 ft lb (50 N•m). Thread sealant should not be used.
17: Install the pump into the manifold.
Before replacing the extractable, make sure that the surfaces
of the packer o-ring and the discharge o-ring seals are clean.
18: Align the positioning dowels of the manifold with the holes in the packer.
19: Push the packer as far as possible against the manifold.
Figure 4.8 Wiring Schematic
ORANGE
BLACK
CAPACITOR
ORANGE
BLACK
RED
IN FROM
ELECTRICAL
CONNECTOR
OUT TO
PUMP PIGTAIL