Symptom:

Jabber  indicator lights up.

Causes:

Frame received on this port exceeds length threshold for Jabber Lockup Protection.

Solution:

If jabber lockup has occurred, it will be automatically re-enabled when the problem
is corrected or the port receives a valid data packet.  Check for a faulty network
interface card that has started transmitting data but never stops.

Symptom:

Power indicator does not light up after power on.

Causes:

Defective power supply or attached cable, or a problem at the power source.

Solution:

Check the power source and attached cable.  If the problem cannot be resolved, you
may have to replace your unit’s power supply.  Ask for dealer assistance.

Specifications

Transmission Technique

: Baseband

Topology

: Tree, Star, Bus (BNC)

Access Method

: CSMA/CD, 10 Mbps

Standard Conformance

  

: IEEE 802.3 10BASE-T

Media Supported

: Category 3,4,5 twisted-pair cable

Interfaces

: 16 standard MDI-X RJ-45 ports, 1 MDI RJ-45 daisy-chain port,
  2 AUI ports, 2 BNC ports

Hub-to-Workstation Distance

: 100m max.

DimensionsDimensions

: 442mm x 141mm x 50mm (17.4" x 5.55" x 1.97")

Power Input

: 100-240 (

™10%) VAC

Power Consumption

: 1 Amp max.

Temperature

: 0°C to 80°C (Standard Operating)

Humidity

: 90% (Noncondensing)

Certification

:

Emissions

: FCC Class A

Safety

: UL, CSA, TÜV/GS

Summary of Contents for EtherHub-16

Page 1: ...artition and reconnection Hardware Installation The EtherHub 16 has 16 RJ 45 ports of which Port 16 can serve as either a standard port or a daisy chain port It also has two AUI BNC ports Use twisted...

Page 2: ...and be sure you do not create any loops in your network connections Connecting to an Ethernet Backbone Thin Ethernet Plug the BNC T type connector into a BNC port on the hub and use this port to conn...

Page 3: ...ments are necessary when connecting to any input voltage in the range marked on the rear panel System Configuration The EtherHub 16 provides standard RJ 45 ports for attaching end node devices such as...

Page 4: ...at both ends of the cable use crossover cabling Note When Port 16MDI is used Port 16MDI X cannot be used BNC Port 10BASE2 This hub has two built in BNC transceivers i e BNC1 and BNC2 on the rear panel...

Page 5: ...g supplied to the hub Collision Flashing Two or more devices are transmitting at the same time This is normal for an Ethernet network However if there are excessive collisions the network may be overl...

Page 6: ...ce Solution Check the power source and attached cable If the problem cannot be resolved you may have to replace your unit s power supply Ask for dealer assistance Specifications Transmission Technique...

Page 7: ...the user at his own expense will be required to take whatever measures are required to correct the interference You may use unshielded or shielded twisted pair 100 STP or UTP for RJ 45 connections War...

Page 8: ...e conductor cord Maximum length of 15 feet Parallel blade grounding type attachment plug rated 15A 125V 240 Volts For UL Listed CSA Certified Cord Set North America Minimum 18 AWG Type SVT or SJT thre...

Page 9: ...s durch berhitzung kommen 6 Versuchen Sie niemals dieses Ger t selbst zu warten da beim ffnen oder Abnehmen des Geh uses die Gefahr eines elektrischen Schlages besteht 7 Keine Gegenst nde auf das Ansc...

Page 10: ...SPECIFICATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY Copyright Copyright 199...

Reviews: