AUI Port

This hub has two built-in AUI transceivers (i.e., AUI1 and AUI2) on the rear panel for connection
using thick Ethernet cable (10BASE5) or fiber optic Ethernet cable (10BASE-F).  To use either
AUI port, set the DIP switches to the correct positions and described on page 2.  An AUI port can
be connected to thick Ethernet by running an AUI drop cable from the hub to a 10BASE5
transceiver attached to the trunk line.  A thick Ethernet segment can be extended up to 300 meters
(1270 feet) and contain up to 500 nodes.  For fiber optic connection, attach a transceiver directly
to the AUI port, and run a point-to-point link up to 2 kilometers (1.24 miles).

Front Panel Indicators

This hub provides LED indicators for monitoring various network conditions. A glance at the
front panel allows you to instantly monitor the status of each station port plus the overall
condition of the hub.

LED

Status

Indication

Jabber

Steady

Packets have exceeded the length threshold for Jabber Lockup Protection on the hub.

Power

Steady

Power is being supplied to the hub.

Collision

Flashing

Two or more devices are transmitting at the same time.  This is normal for an Ethernet
network.  However, if there are excessive collisions, the network may be overloaded.

Link/Rx

Steady

Port is connected to an active node and receiving a valid Link Integrity pulse.

Flashing

Traffic is being received at this port.

Partition

Steady

Port is partitioned off due to faulty cable or connectors, or excessive packet collisions.

Troubleshooting

Symptom:

Link/RX indicator remains unlit.

Causes:

Workstation’s network adapter, cable or hub port is defective.

Solution:

The most common cause is a defective network adapter or cable connection.  Check
the corresponding cable connections, or the workstation’s network adapter for
possible defects.  Verify that the correct cable type (straight or crossover) is being
used.  (Note that crossover cable is only required if you cascade hubs via standard
MDI-X ports; i.e., Port 16MDI is not used.)  Replace the defective cable or adapter.

Symptom:

Partition indicator lights up.

Causes:

Hub has partitioned RJ-45 port due to excessive packet collsions.

Solution:

If port partitioning has occurred, it will be automatically re-enabled when the
problem is corrected or the port receives a valid data packet.

Summary of Contents for EtherHub-16

Page 1: ...artition and reconnection Hardware Installation The EtherHub 16 has 16 RJ 45 ports of which Port 16 can serve as either a standard port or a daisy chain port It also has two AUI BNC ports Use twisted...

Page 2: ...and be sure you do not create any loops in your network connections Connecting to an Ethernet Backbone Thin Ethernet Plug the BNC T type connector into a BNC port on the hub and use this port to conn...

Page 3: ...ments are necessary when connecting to any input voltage in the range marked on the rear panel System Configuration The EtherHub 16 provides standard RJ 45 ports for attaching end node devices such as...

Page 4: ...at both ends of the cable use crossover cabling Note When Port 16MDI is used Port 16MDI X cannot be used BNC Port 10BASE2 This hub has two built in BNC transceivers i e BNC1 and BNC2 on the rear panel...

Page 5: ...g supplied to the hub Collision Flashing Two or more devices are transmitting at the same time This is normal for an Ethernet network However if there are excessive collisions the network may be overl...

Page 6: ...ce Solution Check the power source and attached cable If the problem cannot be resolved you may have to replace your unit s power supply Ask for dealer assistance Specifications Transmission Technique...

Page 7: ...the user at his own expense will be required to take whatever measures are required to correct the interference You may use unshielded or shielded twisted pair 100 STP or UTP for RJ 45 connections War...

Page 8: ...e conductor cord Maximum length of 15 feet Parallel blade grounding type attachment plug rated 15A 125V 240 Volts For UL Listed CSA Certified Cord Set North America Minimum 18 AWG Type SVT or SJT thre...

Page 9: ...s durch berhitzung kommen 6 Versuchen Sie niemals dieses Ger t selbst zu warten da beim ffnen oder Abnehmen des Geh uses die Gefahr eines elektrischen Schlages besteht 7 Keine Gegenst nde auf das Ansc...

Page 10: ...SPECIFICATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY Copyright Copyright 199...

Reviews: