Accton Technology EtherHub-16 Quick Start Manual Download Page 4

EtherHub-16 Quick Start Guide

4

Hardware Description

RJ-45 Ports

This hub has 16 RJ-45 ports that can be used to connect end-node devices (e.g., workstations, file
servers, or printers).  Be sure you have an Ethernet network interface card installed in the device
to be connected to the hub.  Then connect it to any available standard RJ -45 port on the hub (i.e.,
Ports 1~16MDI-X) using straight-through twisted-pair (UTP or STP) cable.

Note: When Port 16MDI-X is used, Port 16MDI cannot be used.

Daisy-Chain Port

A compatible hub or other network interconnection device (e.g., an Ethernet switch) can be
attached to the daisy-chain port (Port 16MDI).  Use straight-through twisted-pair (STP or UTP)
cable to connect to a standard MDI-X port on the target device.  Up to 4 hubs can be cascaded in
this manner.  To connect to another hub, you may also run twisted-pair cabling from an MDI-X
port on this hub to an MDI daisy-chain port on another hub.  However, if you must connect to
another hub via standard MDI-X ports at both ends of the cable, use crossover cabling.

Note: When Port 16MDI is used, Port 16MDI-X cannot be used.

BNC Port (10BASE2)

This hub has two built-in BNC transceivers (i.e., BNC1 and BNC2) on the rear panel for
connection using thin coaxial cable.  To use either BNC port, set the DIP switches to the correct
positions and described on page 2.  A BNC port can be connected to a thin coaxial cable segment
containing up to 30 nodes.  The thin coaxial cable that links the BNC ports may be extended up
to 185 meters and have computers or other Ethernet devices attached to it.  When connecting two
hubs via BNC ports, there should be at least 0.5 meters (1.64 feet) of coaxial cable between the
two BNC ports.  If the hub is at the end of an Ethernet cable, plug and lock the 50-ohm (

)

terminators to the T-type connector on the BNC port.

F

Close off an open end of any T-type connector that is plugged into a BNC port with a 50-

terminator.  In particular, when a hub using the BNC port connection is at the end of an
Ethernet segment, close off the open end of the T-type connector with a 50

 terminator.

Also, if the BNC port is not used, plug a T-type connector into it and close off both ends with
a 50

 terminator.

Summary of Contents for EtherHub-16

Page 1: ...artition and reconnection Hardware Installation The EtherHub 16 has 16 RJ 45 ports of which Port 16 can serve as either a standard port or a daisy chain port It also has two AUI BNC ports Use twisted...

Page 2: ...and be sure you do not create any loops in your network connections Connecting to an Ethernet Backbone Thin Ethernet Plug the BNC T type connector into a BNC port on the hub and use this port to conn...

Page 3: ...ments are necessary when connecting to any input voltage in the range marked on the rear panel System Configuration The EtherHub 16 provides standard RJ 45 ports for attaching end node devices such as...

Page 4: ...at both ends of the cable use crossover cabling Note When Port 16MDI is used Port 16MDI X cannot be used BNC Port 10BASE2 This hub has two built in BNC transceivers i e BNC1 and BNC2 on the rear panel...

Page 5: ...g supplied to the hub Collision Flashing Two or more devices are transmitting at the same time This is normal for an Ethernet network However if there are excessive collisions the network may be overl...

Page 6: ...ce Solution Check the power source and attached cable If the problem cannot be resolved you may have to replace your unit s power supply Ask for dealer assistance Specifications Transmission Technique...

Page 7: ...the user at his own expense will be required to take whatever measures are required to correct the interference You may use unshielded or shielded twisted pair 100 STP or UTP for RJ 45 connections War...

Page 8: ...e conductor cord Maximum length of 15 feet Parallel blade grounding type attachment plug rated 15A 125V 240 Volts For UL Listed CSA Certified Cord Set North America Minimum 18 AWG Type SVT or SJT thre...

Page 9: ...s durch berhitzung kommen 6 Versuchen Sie niemals dieses Ger t selbst zu warten da beim ffnen oder Abnehmen des Geh uses die Gefahr eines elektrischen Schlages besteht 7 Keine Gegenst nde auf das Ansc...

Page 10: ...SPECIFICATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY Copyright Copyright 199...

Reviews: