background image

EtherHub-5st User’s Guide

4

Hub’s RJ-45 Pin Assignments

Schematics for both straight and crossover twisted-pair cable are shown below.  (Note that
crossover cable is only required if you cascade hubs via the RJ-45 station ports; i.e., the 5MDI
Daisy-Chain port is not used.)

      Straight-Through

Crossover

  (Hub)                       (Adapter)                  (Hub)                        (Hub)

1 IRD+

1 OTD+

1 IRD+

 

1 IRD+

2 IRD-

2 OTD-

2 IRD-

 

2 IRD-

3 OTD+

3 IRD+

3 OTD+

3 OTD+

6 OTD-

6 IRD-

6 OTD-

6 OTD-

Specifications

Transmission Technique

: Baseband

Topology

: Tree or Star

Access Method

: CSMA/CD, 10 Mbps

Standard Conformance

  

: IEEE 802.3 10BASE-T

Media Supported

: Category 3,4,5 twisted-pair cable

Interfaces

: 5 RJ-45 station ports, 1 RJ-45 daisy-chain port

Hub-to-Workstation Distance

: 100m max.

DimensionsDimensions

: 120mm x 96mm x 28mm (4.72" x 3.78" x 1.10")

System Power

 

: Requirements - 8VAC, 50/60 Hz, 5 watts

Power Adapter

: Optional external power adapter - 8 VAC, 8VA
  for100V/120V/220-230V/240V

Temperature

: 0°C to 50°C (Standard Operating)

Humidity

: 5% to 95% (Noncondensing)

Certification

: CE Mark

Emissions

: FCC Class B, VCCI Class 2, CISPR Class B

Immunity

: IEC 801-2,3,4, EN60555-2 Class D, EN60555-3

Safety

: UL, CSA, TÜV/GS

Pin

MDI-X Assignment

(port 1~5)

MDI-Assignment

(Daisy-Chain Port)

1

Input Receive Data +

Output transmit Data +

2

Input Receive Data -

Output transmit Data -

3

Output transmit Data +

Input Receive Data +

6

Output transmit Data -

Input Receive Data -

4,5,7,8

Not Used

Not Used

Summary of Contents for EH2045S

Page 1: ...5S Quick Start Guide Power Adapter optional Hardware Description Frant and Side Panels and Hub Stand To stand the hub upright on a desk or nearby shelf slide the stand onto the base of the hub To lay...

Page 2: ...s hub to a crossover port on the other hub However if you must connect to another hub via stations ports at both ends of the cable use crossover cabling Power Socket The power adapter optional plugs i...

Page 3: ...Check the corresponding cable connections or theworkstation s network adapter for possible defects Verify that the correct cable type straight or crossover is being used Note that crossover cable is...

Page 4: ...5 twisted pair cable Interfaces 5 RJ 45 station ports 1 RJ 45 daisy chain port Hub to Workstation Distance 100m max DimensionsDimensions 120mm x 96mm x 28mm 4 72 x 3 78 x 1 10 System Power Requirement...

Page 5: ...ar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct...

Page 6: ...il Directive 89 336 EEC Article 4a Conformity is declared by the application of EN55022 1987 Class B CISPR 22 1985 BS 6527 1988 CE Mark Declaration of Conformance This is to certify that this product...

Page 7: ...efahr eines elektrischen Schlages besteht 7 Keine Gegenst nde auf das Anschlu kabel stellen damit es nicht durch scharfe Kanten zerst rt werden kann 8 Keinerlei Gegenst nde durch die ffungen in das Ge...

Page 8: ...ATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY OTHER LIABILITY Copyright Copyright 1995 by Acc...

Reviews: