background image

14

www.acclaimlighting.com

TESTING EMITTER OUTPUT

After you have addressed each Flood One EO Color fixture we recommend that you also 
test each one prior to installation. This can be achieved with your RDM (Remote Device 
Management) tool. Various third party DMX/RDM tools are available; we recommend the 
Acclaim Lighting XMT-350 for this task.

TO TEST EMITTER OUTPUT USING THE ACCLAIM LIGHTING XMT-350

1  Connect the XMT-350 to the DMX input line of either a single fixture or multiple fixtures in 

a pre-arranged daisy chain configuration.

2  Power on the fixture(s) and the XMT-350.
3  On the XMT-350, press the 

MODE

 button, then use the arrow buttons to highlight the 

SEND

 function and press the   button to select. 

4  Use the arrow buttons to determine the DMX output:

 

Use the left and right buttons to choose the DMX address,

 

Use the up and down buttons to increase/decrease the level at the chosen address. 

Note: If you wish to send DMX values to all addresses simultaneously (rather than cycling 
through them individually), when the XMT-350 is showing address 001, press the left button 
once to change to 

ALL CHANNELS

. Now when you set the level it will affect all emitters equally.

  

Summary of Contents for Flood One EO Color

Page 1: ...Flood One EO Color User guide...

Page 2: ......

Page 3: ...unt 6 Using a pipe clamp 7 Power and control wiring 8 Wired DMX control 9 Optional wireless DMX operation via Aria 10 CONFIGURATION 11 Making a temporary control link with the XMT 350 11 Addressing fi...

Page 4: ...d DMX RDM format and with the addition of the optional Acclaim Lighting Aria units see page 10 you can add remote wireless connectivity to the list of abilities within the Flood One EO Color range The...

Page 5: ...3 www acclaimlighting com SUPPLIED ITEMS Standard model Half snoot model standard model plus FBHSG Full snoot model standard model plus FBFSG...

Page 6: ...ighting com OPTIONAL ACCESSORIES Tenon mounts 2 pipe 2 51 56mm inner dia TM2 4 pipe 4 13 105mm inner dia TM4 Pipe clamps each can mount 1 or 2 fixtures 2 pipe 2 51 56mm inner dia PC2 4 pipe 4 13 105mm...

Page 7: ...around the center line see page 17 The yoke has a thickness of 0 24 6mm Select bolts or screws not supplied that fit the yoke holes correctly and are particularly suited to the mounting surface Option...

Page 8: ...the pole Tenon mounts must NEVER be used to hang a Flood One EO Color below a pole TO USE A TENON MOUNT 1 Slide the tenon mount onto the vertical pole and secure using the two bolts on the side 1 4 6m...

Page 9: ...h side to join the two halves see below about the correct use of the supplied washers 4 Tighten the two main bolts evenly until the clamp is held firmly in place 5 Use one of the two smaller bolts wit...

Page 10: ...is derived from a suitable overload protected supply the junction boxes have an environmental rating of at least IP66 all cable access points plus the enclosure cover are correctly sealed and moistur...

Page 11: ...rder feed fixtures located in different directions use a powered DMX splitter buffer Ensure that the DMX and DMX connections do not become crossed at any point WIRED DMX CONTROL When connecting multip...

Page 12: ...acclaimlighting com OPTIONAL WIRELESS DMX OPERATION VIA ARIA Where wireless control is required use Acclaim Lighting Aria wireless linking over distances up to 2600 feet 792m line of sight DMX DMX IN...

Page 13: ...recommend the Acclaim Lighting XMT 350 for this task Flood One EO Color control cable XLR lead from XMT 350 Gray Gray Red Red Black Black DMX Hot DMX Cold Ground MODE 100 50 CH CH 0 toggle func MAKING...

Page 14: ...D ONE EO COLOR FLOOD ONE EO COLOR 005 009 012 PATCH OPTIONS 004 004 FLOOD ONE EO COLOR 001 The fixture that is highlighted within the list should begin flashing its emitters to identify itself 4 On th...

Page 15: ...should show output from its emitters to identify itself 3 If necessary use the up down buttons to highlight an alternative fixture 4 Press the button to view details for the chosen fixture and then us...

Page 16: ...ixtures in a pre arranged daisy chain configuration 2 Power on the fixture s and the XMT 350 3 On the XMT 350 press the MODE button then use the arrow buttons to highlight the SEND function and press...

Page 17: ...ithin the fixture matches that being output by the controlling source device Check the DMX output near to the source to confirm a valid signal is being originated Check that the DMX hot and DMX cold l...

Page 18: ...DM Maximum lengths in series 32 via DMX power local to each fixture Power input 100 277VAC 50 60Hz Power consumption 65W Housing Die cast aluminum glass lens optional marine coating available Mounting...

Page 19: ...17 www acclaimlighting com DIMENSIONS 10 63 270mm 11 81 300mm 2 13 54mm 5 71 145mm 0 47 12mm 4 25 108mm 6 26 159mm 13 07 332mm 6 3 160mm STANDARD MODEL...

Page 20: ...18 www acclaimlighting com 10 63 270mm 11 81 300mm 2 13 54mm 5 71 145mm 4 25 108mm 7 83 199mm 13 07 332mm 6 3 160mm 0 47 12mm HALF SNOOT MODEL...

Page 21: ...19 www acclaimlighting com 10 63 270mm 11 81 300mm 2 13 54mm 5 71 145mm 4 25 108mm 7 83 199mm 13 07 332mm 6 3 160mm 0 47 12mm FULL SNOOT MODEL...

Page 22: ...rd party items not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and...

Page 23: ......

Page 24: ...www acclaimlighting com...

Reviews: