Summary of Contents for AJBOX1

Page 1: ...AJBOX1 User guide...

Page 2: ......

Page 3: ...elcome 2 Part code 3 Important notes 3 INSTALLATION 4 Cable prep 4 0 10V 4 DMX 5 Connecting the AJBOX1 6 Additional environmental protection 13 FURTHER INFORMATION 14 Specifications 14 Dimensions 15 L...

Page 4: ...NPT thread Combined feed output NPT thread Control input NPT thread HV LV barrier Surge protector IP66 lid Shown here with cable gland inputs rather than conduit fixtures INPUT FIXTURES GLANDS You wil...

Page 5: ...cautions for external surge protection as control and power electronics can be damaged by major events Ensure that the mains input is derived from a suitable overload protected supply all cable access...

Page 6: ...lity without filling the box with excess cable CABLE PREP 0 10V Prep your cables as shown below when using a 0 10V control system with a combined output cable 1 2 3 2 76 3 15 0 10 20 30 40 50 60 70 80...

Page 7: ...n using a DMX control system with a combined output cable The DMX hot and cold out connections red white and white black striped are not used and can be trimmed We suggest that you cut them short at s...

Page 8: ...6 CONNECTING THE AJBOX1 1 Begin by removing the lid and also the blanking plugs on the main inlet outlet holes 2 Phillips driver 13 16 30mm A F 15 16 24mm A F NPT thread NPT threads...

Page 9: ...ding down the connector blocks there is no need to remove the screws completely 5 Ensure that the incoming AC power is fully isolated Prep the AC input cable as shown on page 4 then insert it through...

Page 10: ...small button to open the internal spring contacts b Carefully push the correct wire into the vacant hole until the bare conductor goes all the way in c Release the small button and check by gently pu...

Page 11: ...can be more easily manipulated Control input cable via 3rd party conduit fitting or cable gland Note Although the three contacts of the control connector block are labeled and we recommend that you d...

Page 12: ...ocks taking great care to ensure that the various wires are mated only with the correct terminals see pages 4 and 5 for wire designations For each input a Press down on the lever to open the internal...

Page 13: ...t to the thread of the large cable gland and run a finger round it to spread the sealant across all parts of the thread 12 Ensure the strain relief cap is loose then carefully screw the body of the gl...

Page 14: ...nsure the strain relief locking caps are loose then carefully screw the bodies of each gland into their inlet holes and tighten them using an adjustable wrench Fitting gland body Strain relief locking...

Page 15: ...tightness ADDITIONAL ENVIRONMENTAL PROTECTION If the AJBOX1 is to be externally wall mounted in a vertical orientation it is advisable to apply extra silicone sealant into and around the strain relie...

Page 16: ...le Internal connections Two 3 conductor push terminals for AC and control links Maximum conductor size 12 AWG Maximum input voltage 390VAC Maximum connection current 15A Maximum total line power 120VA...

Page 17: ...15 DIMENSIONS 3 07 78 mm 4 41 112 mm 5 51 140 mm 4 72 120 mm 0 2 5mm...

Page 18: ...16...

Page 19: ...ms not manufactures by Acclaim lighting During the period specified above Acclaim Lighting will replace defective parts at its expense and will absorb all expenses for warranty service and repair labo...

Page 20: ...www acclaimlighting com...