Remarks: 

the Zone 2, it can be used to operate a doorbell if there is no need to operate a second door. The 

wiring to connect the doorbell is via NO2 and COM2. Press 

#

, the R3K will send out a switching signal to the 

doorbell, as long as you press the” 

#

”, the doorbell will operate, it will stop when you release the ” 

#

” 

 

Relay operation (Pulse mode and Toggle mode) 

Both of the two relays can operate in Pulse Mode (suitable for access control) or Toggle Mode (suitable for 
arming/disarming alarms, switching lights, machines….etc)   
 
Every time a valid fob/card or Pin is read/input in Pulse Mode, the relay will operate for the pre-set relay pulse 
time 
Every time a valid fob/card or Pin is read/input in Toggle Mode, the relay changes state and will not turn back 
until the fob/card is presented or the PIN used   

 

Anti-Tamper Alarm 

The R3K uses an LDR (light dependent resistor) as an anti tamper alarm. If the keypad is removed from the 
cover then the tamper alarm will operate   

 

Sound and LED indication 

Operation Status 

Red LED 

Green LED 

Blue LED 

Buzzer 

Zone 1, unlock 

Bright 

Short Ring 

Zone 2, unlock 

Bright 

Short Ring 

Power on 

Bright 

 

Long Ring 

Stand by 

Shines slowly 

Off 

Press keypad 

Short Ring 

Operation successful 

Bright 

Long Ring 

Operation failed 

3 Short Rings 

Enter into programming mode 

Bright 

off 

Long Ring 

In the programming mode 

Bright 

Bright 

Exit from the programming mode 

Shines slowly 

Long Ring 

Alarm 

Shines quickly  - 

Alarm 

                   

 

 

 

 

Summary of Contents for KP-KR3

Page 1: ...KP KR3 Stand Alone Keypad Proximity Card Reader User Manual...

Page 2: ...or door access not only for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons Features Weather resista...

Page 3: ...nvironment Conforms to IP68 Adjustable Door Relay time 1 99 seconds Adjustable Alarm Time 0 3 minutes Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions H 128 x W 82 x D 28 mm...

Page 4: ...the supplied rubber bungs to waterproof the screw holes Attach the keypad to the back cover Wiring cable Color Function Description Grey Black GND Negative pole Grey Alarm Alarm Negative Yellow Black...

Page 5: ...Zone 1 and any number between 1101 1200 for Zone 2 The PIN is any 4 8 digits between 0000 99999999 with the exception of 1234 which is reserved Users can be added continuously without exiting programm...

Page 6: ...agram Examples Common power supply for magnetic lock Fail open power to lock Common power supply for lock release Fail secure power to unlock Common power supply for auto gate controller using Normall...

Page 7: ...pre set relay pulse time Every time a valid fob card or Pin is read input in Toggle Mode the relay changes state and will not turn back until the fob card is presented or the PIN used Anti Tamper Ala...

Page 8: ...is by Card and PIN together Note When adding users if the Card or Pin user has been enrolled already you can not add it again The R3K will give a bleep as error Factory default setting Card or PIN mod...

Page 9: ...mber 8 digits Card number Card quantity Card quantity is between 1 1100 Of the 8 digits card number it is the last 8 digits on the card To delete Card users by cards Note Users can be deleted continuo...

Page 10: ...PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New PIN New PIN To change a PIN in ca...

Page 11: ...tic Signal Door Bell Settings Door Open Detection Door Open Too Long DOTL warning When used with an optional magnetic contact or built in magnetic contact of the lock if the door is opened normally bu...

Page 12: ...tic Signal The acoustic signal can be set on or off When on the R3K will bleep when buttons are pressed when off the R3K will be in silent mode Normal status On 8 6 Factory default setting Acoustic si...

Page 13: ...r off then press and hold the button and power on release it after you hear two bleeps the LED will turn orange After 10 seconds it will turn red and bleep once to confirm factory default is successfu...

Reviews: