1. Correctly connect the Control Box, Handset, Power Cord, Lifting Column & Patch Cord. (Picture 1).

    

   Plug the power cord into 110~220VAC outlet the LCD display will display will display current height.

Reset (Initialization):

Press and hold the down button, the handset will display “rES” and the desk will begin to lower, until 

to the lowest height then slightly rise. Continue holding the down button until the Handset displays the 

lowest height. 

If the handset continues to display “rES” once the down button has been released, press and hold the 

down button until the Handset displays the lowest height.

3. After reset, press and hold “UP” button, lifting column will rise, release to stop.

4. After reset, press and hold “DOWN” button, lifting column will lower, release to stop.

Setting Memory Positions:

After pressing and holding UP/DOWN button to a height, press button M first, then press button 1, this 

height will be remembered by button 1.

Still pressing and holding UP/DOWN button to another height, press button M, then press button 2, this 

height will be remembered by button 2.

The same way, the button 3, 4 can remember other heights. After memory, press 1/2/3 button, desk will 

motion to the height it remembers, press “UP” and “DOWN” button. The motion will be stopped.

C. DIRECTION FOR USE

D. TROUBLE SHOOTING

If the LCD Controller displays error codes when raising or lowering the desk, a reset will be required.

1. Motor error (E01, E02 or E03, E04) 

Control box cannot detect motor halt plate signal or Control box detect one lifting column is over loaded. 

This is a safety protection.

Please take away any large loads from the desk top and reset the controller. Should a reset fail to resolve 

the issue one or more motors will need to be replaced.

2. Control box temperature protection (HOT)

This indicates that the control box temperature is above 750C or the system has been in continuous use for 

2min or more. The lifting columns are locked out for up to 18mins as a safety precaution. For an urgent 

reset, unplug the power cord.

3. Overload protection (E07)

Desk load in excess of 100kg, user needs to reduce load, then reset or just need to wait for 3 seconds, 

it will recover.

Summary of Contents for DUO II

Page 1: ...DUO II ELECTRIC SINGLE DESK ASSEMBLY AND INSTRUCTION GUIDE...

Page 2: ...2 www accentworkspaces co nz Tools Required Battery Drill 4mm Hex Bit 2 Square Drive Bit Assembly Instructions 3 6 User Instructions 7 13 Care and Maintenance 14 TABLE OF CONTENTS...

Page 3: ...0800 126 826 support accentworkspaces co nz 3 A ASSEMBLY DIAGRAM DUO II ELECTRIC SINGLE DESK...

Page 4: ...ssion Tube 1pc 8 Hex Bar 1pc 9 Lifting Column 1pc B PACKING LIST ACCESSORY PACKAGE QUANTITY 10 Screw ST6x23 15pcs 11 Bolt M6x10 5pcs 12 Bolt M6x16 8pcs 13 Glide 4pcs 14 Cable Ties 2pcs 15 Hex Wrench 2...

Page 5: ...hex wrench Install foot and levelling glides Install the lifting column insert the screw into the keyhole of the lifting column and pull to one side then fasten the M6x10 with a 4mm hex wrench Insert...

Page 6: ...he desktop and handset Our control box and AC adaptor are pre fixed to the bracket hang the bracket to frame and put on desktop Tighten the bolt x4 M6x10 and transmission tube M6x10 4pcs ST6x23 14pcs...

Page 7: ...Shooting D 10 Warranty E 11 Changing between CM and Inch 1UN F 11 Setting Handset Display Brightness 2BR G 11 Adjust Upward Sensitivity 3FU H 12 Adjust Downward Sesitivity 4FD I 12 Adjust the Lowest...

Page 8: ...3 Control Box 1pc 4 AC Adaptor 1pc 5 Power Cord 1pc A PARTS LIST NO 1 Input 110 240VAC 2 Output Power 24VDC 3 Load Capacity 800N 4 Speed 20mm s 5 Stroke 450mm 6 Min Install Dimension 700mm 7 Operatio...

Page 9: ...UP DOWN button to another height press button M then press button 2 this height will be remembered by button 2 The same way the button 3 4 can remember other heights After memory press 1 2 3 button de...

Page 10: ...N CM AND INCH 1UN Keep pressing Button M for 3 seconds Handset will display S then release pressing Button M and press Button M again the code 1Un will then appear Press Button M to enter 1 It will di...

Page 11: ...quit please wait for 2 seconds and it will display current height J ADJUST THE LOWEST HEIGHT DISPLAY AND HEIGHT RANGE 5SH 1 Keep pressing Button M for 3 seconds Handset will display S then release pr...

Page 12: ...button M to preserve and quit rES will appear need a reset to finish restoring factory setting About reset please refer to Step C L ADJUST BOUNCE HEIGHT 7H 1 Keep pressing button M for 3 seconds Hand...

Page 13: ...o preserve 4 You can press UP button to begin fatigue test also you can quit the fatigue test by unplugging the power cord O HANDSET LOCK 1 Keep pressing Up and Down button for 5 seconds handset will...

Page 14: ...d berry juices first aid preparations concentrated bleach oven cleaners dishwasher detergents artificial dyes hair colouring and solvent based pen ink immediately Specialty glues such as Super Glue mu...

Page 15: ...and joining the team is effortless Approximately three months after your product delivery one of our team members will reach out to you for a brief call During this conversation we will enquire about...

Page 16: ...0800 126 826 support accentworkspaces co nz 22 Hood Street Wellsford Auckland 0900 New Zealand Version 011123...

Reviews: