Sleep Timer Setting  [ SLEEP ]

1. Sleep Timer settings can also be configured in the Acaia apps.

2. The number indicates the amount of time before the scale automatically powers off. For example, 

when 10 is selected, the scale powers off after 10 minutes of being idle if the scale is disconnected 

from all mobile devices. 

Zero Tracking Setting [ trAcE ] 

1. Zero Tracking is a function for automatically maintaining the zero indication within certain limits.

2. Off: It is not recommended to turn off Zero Tracking because the zero indication can drift easily 

as the room temperature changes.

3. 0.5 d~3 d: Zero Tracking is measured in units of division, or “d”. 1d is equal to 0.01 grams. For 

example, if Zero Tracking is set to 3 d, any weight less than .03 grams will automatically be zeroed.

4. 1 d is recommended in general for the Acaia Pyxis.

Key Sound Setting  [ bEEP ]

1. Key Sound settings can also be configured in the Acaia apps.

2. Set the Key Sound function to on/off to enable/disable the beeping sound.

Zero Range Setting  [ 0 rAnGE ] 

1. The Zero Range setting determines the range for which the Tare button executes zero operation 

instead of tare operation.

2. When Zero Range is set to 2, the range for zero-setting will be 2% of the capacity, i.e., ± 10 g for 

Acaia Pyxis. By pressing the Tare button, any weight within ± 10 g is zeroed out by zero operation 

while any weight that lies outside the range is tared out by tare operation.

3. If Zero Range is set to 100, the range for zero-setting will be 100% of the capacity, i.e., ± 500 g 

for Acaia Pyxis. Therefore, instead of tare operation, zero operation would be executed in this set-

ting whenever the Tare button is pressed.

Notice: The difference between zero operation and tare operation is that zero operation would sim-

ply ignore the weight and display as 0 while tare operation would deduct the weight from the weigh-

ing result. However, zero operation does not increase the scale capacity. 

Weighing Filter Setting  [ Filt. ] 

1. The Weighing Filter Setting determines the speed at which the load receptor responds to weight 

and determines the weighing value. The larger the number, the more stable but slower the weighing 

result will be. The number shown on the LED display indicates the current filter setting.

2. Press the Tare button to change the parameter.

Default Unit Setting  [ Unit ]

 

1. The Default Weighing Unit is set to grams if [ 9 ] is selected and ounce if [ o2 ] is selected.

Weighing Mode Setting  [ NOdE_1 ] 

1. The Weighing Mode is set to On by default.

   • On: The Weighing Mode is enabled.

   • Off: The Weighing Mode is disabled.

Dual Display Mode Setting [ NOdE_2 ] 

1. The Dual Display Mode is set to On by default.

 • On: The Dual Display Mode is enabled.

 • Off: The Dual Display Mode is disabled.

 

9

.

Summary of Contents for AC002

Page 1: ...Acaia Pyxis User Manual FW 1 0 019 AC002...

Page 2: ...Units Product Care Information Battery Charge Calibration Care and Cleaning Mode Introduction Mode 1 Weighing Mode Mode 2 Dual Display Mode Mode 3 Auto Start Mode Configuration Appendix Button Functi...

Page 3: ...uctions in this user manual apply to the Acaia Pyxis You have purchased a quality precision weighing scale that requires handling with care Make sure to read through this user manual prior to using th...

Page 4: ...ct a horizontal surface that is stable and vibration free to set up the scale Press to turn on the scale Double tap to turn off the scale Short press to tare zero the weight Press and hold to switch m...

Page 5: ...e the scale is in the weighing mode and the unit is set to gram then tap T button rapidly Keep tapping T button until CAL is shown on the display Place a 100 g weight on the scale and wait until the d...

Page 6: ...display shows 0 00 0 000 If the weight exceeds 500 00 grams the scale will display _ _ _ _ The maximum time that can be displayed is 9 minutes and 59 seconds When the limit is reached the timer still...

Page 7: ...right in ounces The timer displays from 00 to 99 Display Mode Description This mode is designed to measure the time of the shot starting from the first few drops of espresso The scale will perform th...

Page 8: ...d Tare button Exit Settings Tap Power button Setting Display Options Default Sleep Timer SLEEP 5 10 20 30 60 Off 5 Zero Tracking trAcE 0 5 d 1 d 2 d 3 d Off 1 d Key Sound bEEP On Off On Zero Range O r...

Page 9: ...is By pressing the Tare button any weight within 10 g is zeroed out by zero operation while any weight that lies outside the range is tared out by tare operation 3 If Zero Range is set to 100 the rang...

Page 10: ...the sensitivity of ow detection in the droplet icon modes Smaller value indicates higher sensitivity but is recommended only for stable working environments 3 Tap the Tare button to toggle through the...

Page 11: ...ettings Menu tap to go back to Modes Tare Button Tare Tap to perform tare operation Toggle units Long press to switch between gram and ounce in Weighing Mode Switch option While in Settings tap to adv...

Page 12: ...tery is fully charged The indicator starts flashing or does not light up when the USB cable malfunctions Tare Operation Bluetooth Connected The LED indicator on the lower left flashes when the Tare bu...

Page 13: ...Over load the weight is over the maximum capacity Under load the weight is under the minimum capacity 304 Calibration error Calibration cannot proceed when environmental noises are too strong Please...

Page 14: ...05 g Linearity 1 d 2 d d 0 01 g 0 05 g Indication Limit 515 g 18 16 oz Power Supply 5 V 500 mA Battery Lithium ion rechargeable 3 7 V 310 mAh Battery Life Up to 7 hours Display LED Material Aluminum...

Page 15: ...l rights reserved No part of this manual may be reproduced processed duplicated or published in any form by photocopying microfilming reprinting or any other method in particular electronic means with...

Reviews: