background image

- 10 - 

 
TROUBLE-SHOOTING CHECK LIST 

 

SYMPTOMS 

 

A - Siren motor does not start and siren does not rotate. 

 

 

POSSIBLE CAUSE   

 

CORRECTIVE PROCEDURE 

 

1.No power to motor controls 

1.Check fuses and power supply 

 

2.Defective magnetic starter relay 

2. Replace relay 

 

3.Burned or pitted magnetic starter relay 

3. Replace relay 

 contacts 

 

4.Loose connections in control panel 

4.Check and repair 

 

5.Overload is kicked out on starter relay 

5.Trace overload and correct the cause 

 

6.Electric motor windings either open or 

6.Test motor and replace 

 shorted 

 

7.Remote actuating system defective 

7.Trouble-shoot and correct 

 

8.Worn collector rings or brushes 

8.Replace 

 

9.Dirty or corroded collector rings 

9.Clean and polish 

 

10.Loose connection on collector ring assembly 

10.Trace and repair 

 

11.Ice in siren rotor-stator 

11.De-ice with hot antifreeze or hot air blower. 

 

 

 

Do not use flame near fiberglass 

 

B - Siren operates with difficulty or erratically. 

 

 

POSSIBLE CAUSE 

CORRECTIVE PROCEDURE 

 

1.Siren air intake clogged 

1. Clear obstruction 

 

2.Build-up of foreign material between siren 

2. Disassemble housing and clean. Air gap 

 

rotor and stator 

 

should be .025 inch or more. 

 

3.Rotation mechanism binding 

3. Inspect to determine cause and free-up or 

 

 

 

replace defective parts 

 

C - Siren sounds but does not rotate. 

 

 

POSSIBLE CAUSE 

 

CORRECTIVE PROCEDURE 

 

1.Foreign material jamming rotating 

1.Clear obstructions 

 mechanism 

 

2.Defective gear reducer 

2.Replace 

 

3.Broken jaw coupling 

3.Replace 

 

4.Loose setscrew on jaw coupling 

4.Retighten 

 

5.Improper torque adjustment on drive chain 

5.Adjust torque spring to correct slippage 

 assembly 

 

6.Chain slipping or off track 

6.Adjust torque spring or replace chain 

 

7.Broken drive chain 

7.Repair broken links 

 

8.Upper or lower bearing seized 

8.Free-up and lubricate or replace

Summary of Contents for ALLERTOR 125

Page 1: ... 1 INSTALLATION OPERATION MAINTENANCE And PARTS MANUAL 4801 W Woolworth Ave Milwaukee WI 53218 Phone 414 358 8000 Fax 414 358 8008 ALLERTOR 125 ROTATING DIRECTIONIAL SIREN ...

Page 2: ...SASSEMBLY REPAIR REPLACEMENT AND REASSEMBLY 11 PREPARATION FOR RESHIPMENT 11 STORAGE 11 PARTS LIST 12 14 Control Panel for 3 Phase 2 Signal Siren 12 Control Panel for Single Phase 2 Signal Siren 13 Control Panel for 3 Phase 3 Signal Siren 14 Siren Assembly 15 17 ILLUSTRATIONS Figure Page 1 Roof Mount 5 2 Parapet Mount 5 3 Chimney Mount 5 4 Tower or Tank Mount 5 5 Siren Support Platform 5 6 Work Pl...

Page 3: ...ing 1 Direct mechanical switch 2 Telephone relay system 3 Radio relay system 4 Program timer 5 Any combination of the above SPECIFICATIONS Weight Allertor 125 2 signal 425 lbs Allertor 125 3 signal 450 lbs Dimensions Overall assembly 7 ft long 3 ft wide 5 ft high ACOUSTICAL DATA Output level 126 DB at 100 feet Output frequencies Standard dual tone 523 698 hertz Special single tone 465 hertz Specia...

Page 4: ...not mount siren too high so that the sound goes over the top of the area In lieu of a suitable existing structure for mounting a cedar pole approximately 40 50 feet long and sunk 8 feet deep is a generally recommended mount Refer to the illustrated mounting layouts for details Any tall building trees hills or other obstructions will tend to create a barrier which will produce a deadened area behin...

Page 5: ...sign will be dictated by building construction and height desired CHIMNEY MOUNT FIGURE 3 A sturdy chimney may provide a convenient support for mounting the siren The possibility of corrosive or staining smoke should be considered when this type of installation is planned Use 4 heavy wall galvanized pipe to a maximum height of 10 feet above the top of the chimney Use larger pipe for greater height ...

Page 6: ... 6 ...

Page 7: ... 7 ...

Page 8: ... and not the eyebolt on the siren The gear reducer end of the siren should lead the way up as the siren and pole are raised to the vertical position see Figure 8 c The fiberglass horn may be assembled to the compression chamber before erection provided no weight is put on the horn and it does not interfere with erection d With the pole and siren in final position proceed with electrical connection...

Page 9: ...nstalled under the base in the center of the assembly This bearing has an external grease fitting and has been lubricated at the factory so no additional lubricant is necessary for one year When greased one shot of the grease gun is sufficient If excess flows from the seals remove it from inside the base with a rag Use Molub Alloy 171 graphite grease manufactured by the Imperial Oil and Grease Co ...

Page 10: ...r stator 11 De ice with hot antifreeze or hot air blower Do not use flame near fiberglass B Siren operates with difficulty or erratically POSSIBLE CAUSE CORRECTIVE PROCEDURE 1 Siren air intake clogged 1 Clear obstruction 2 Build up of foreign material between siren 2 Disassemble housing and clean Air gap rotor and stator should be 025 inch or more 3 Rotation mechanism binding 3 Inspect to determin...

Page 11: ...T AND REASSEMBLY The siren s physical design is such that it precludes most mechanical problems other than those caused by natural disasters or violent physical damage The siren configuration is constructed from reinforced fiberglass and bolted together to form a weatherresistant enclosure for all moving parts The parts drawing Figure 15 illustrates component placement Upon removal of the fibergla...

Page 12: ...ON NO REQ D 12 20100 CONTROL PANEL ASSEMBLY Complete REF 1 20101 ENCLOSURE NEMA 12 Furnas for maometic starter 14EF32AC71 1 2 20102 PANEL Interior mounting 1 3 20103 STARTER Magnetic Furnas size 1 3 4 NEMA 1 4 20104 SWITCH Operating optional 1 5 20105 OVERLOAD Bi metal 31 5 amp for 230V siren 1 6 20106 COUNTER 230 volt optional 1 7 20108 BLOCK Terminal 1 ...

Page 13: ...mounting 1 3 20203 STARTER Magnetic single phase size 2 NEMA 1 4 20204 OVERLOAD Bi metal 60 axnp for 230V siren 2 5 20205 RELAY Current sensing for No 10234 motor for start capacitor 1 6 20206 CONTACTOR Start 1 7 20207 CAPACITOR Start for No 10234 motor 4 8 20208 CAPACITOR Run for No 10234 motor 3 9 20209 COUNTER 230 volt optional 1 10 20211 BLOCK Terminal 1 11 20212 SWITCH Manual optional 1 ...

Page 14: ...MBLY Complete REF 1 20301 ENCLOSURE NEMA 12 Furnas for magnetic starter 22EF32A71 1 2 20302 STARTER Magnetic Furnas 1 3 4 size reversing type includes mounting panel 1 3 20303 SWITCH Operating optional 1 4 20304 OVERLOAD Bi metal special type from A C A 3 5 20305 COUNTER 230 volt optional 1 6 20306 BLOCK Terminal 1 ...

Page 15: ... 15 ...

Page 16: ... Drive with sprocket 1 12C AL 125 12C KEY Drive shaft 1 12D AL 125 12D GASKET 1 13 AL 125 13 LIMITER ASSEMBLY Torque includes bushing and arm 1 14 AL 125 14 COLLAR 5 8 in I D 1 15 AL 125 15 SPRING Torque setting 1 16 AL 125 16 COVER Chain 1 17 AL 125 17 DRIVE ASSEMBLY Base rotator 1 17H Coml CHAIN Base rotator No 35 standard 68 11 16 in plus 1 connector 1 18 AL 125 18 BEARING Upper rotator 1 1 4 i...

Page 17: ...H40 Coml SCREW Hex hd cap 3 8 18 x I in 6 H41 Coml WASHER Internal star 3 8 in 6 H42 Coml SCREW Hex hd cap 3 8 18 x 1 1 4 in 1 H43 Coml NUT Hex 3 8 18 8 H44 Coml SCREW Hex hd cap 3 8 18 x 1 1 2 in 1 H45 Coml SETSCREW 5 16 18 x 5 16 in 2 H46 Coml NUT Brass No 10 32 6 H47 Coml NUT Hex hd jam 1 2 13 2 H48 Coml SCREW Hex hd cap 5 8 11 x 2 1 4 in 4 H49 Coml WASHER Flat 5 8 in 4 H50 Coml WASHER Internal...

Reviews: