Page 1: ...USER MANUAL USER MANUAL CONTROLLER 69 WIFI ...

Page 2: ...roduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA ...

Page 3: ...ns with EC motors may be used with this controller using a Molex adapter An EC motor fan will have two cords coming out of its motor box for the power and the controller Note that certain models that previously used DC motors now contain EC motors in updated builds EC Motor Compatible AC or DC Motor NOT Compatible Please visit www acinfinity com to check for the latest models compatible with this ...

Page 4: ...ler Mounting Universal Infinity SystemTM UISTM Compatibility Adding More Devices Programming Maximum and Minimum Settings Other Settings Download the App Add a Device FAQ Other AC Infinity Products Warranty Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 12 Page 15 Page 16 Page 17 Page 19 Page 34 Page 35 Page 36 Page 37 Page 42 Page 45 Page 46 ...

Page 5: ... not cover power cords with rugs or other fabric materials This product pairs with those that has rotating parts Safety precautions should be exercised during the installation operation and maintenance of this product Do not insert or allow fingers or foreign objects to enter any ventilation or exhaust openings as it may cause electric shock fire or damage to this product Do not block or tamper wi...

Page 6: ...proper functionality and to prevent radio frequency interference from affecting your sensor probe TIP 1 Keep the probe cord far away from your ballast s cords to ensure the controller properly detects climate conditions You may also wrap the probe cord and create a cone around the sensor head with aluminum foil tape TIP 2 Do NOT plug your grow light and inline fan into the same duplex outlet Plug ...

Page 7: ...ORING LCD display shows key data like temperature humidity device levels trends time countdowns and more UIS CONNECTIVITY Connect up to four devices to simultaneously set programming for all devices or independently for each device ADVANCE SETTINGS Additional setting options include Fahrenheit Celsius toggling clock calibrations and custom transitions VERSATILE PLACEMENT Mount the controller on a ...

Page 8: ...9 PRODUCT CONTENTS WIRE TIE x1 WOOD SCREWS WALL HANG x2 SMART WIFI CONTROLLER x1 SENSOR PROBE x1 UIS M 4PIN F ADAPTER x2 CONTROLLER PLATE BOLTS x2 ...

Page 9: ...TUP STEP 1 Plug your device s UIS connector into one of the controller s ports STEP 2 Plug the sensor probe into the controller s 3 5mm jack Set the probe near your plants in your grow tent for the most accurate reading ...

Page 10: ...unts wood screws and zip ties to cable manage the cords Secure the tie mounts onto a surface using the wood screws Loop the zip ties around the cords into the tie mounts STEP 3 Plug your device s power cord into an AC power outlet to power it and the controller ...

Page 11: ...NG STEP 1 WALL MOUNTING Locate a spot free of obstruction and secure the anchors into your wall Twist the wood screws into the anchors STEP 2 WALL MOUNTING Hang the controller by the screws using the holes on the backside ...

Page 12: ...he upper half of the plate Hang the controller by the bolts using the holes on the backside MAGNET MOUNTING You may also mount the controller onto a steel surface using the magnet located behind the label CONTROLLER MOUNTING Controller plate not included ...

Page 13: ...en the stand behind the controller to set it tilted on your desktop CORD ARRANGEMENT Cords may be routed into or outside of the kickstand grooves and through a cut hole behind the controller CONTROLLER MOUNTING T SERIES ...

Page 14: ...that will activate your devices based on your grow tent s temperature and humidity Create independent timers and schedules for customized activation in your desired timeframe Your grow system can be regulated using your controller hub or remotely on the AC Infinity app paired with compatible controllers where you will have access to automation programming and climate data Grow devices will be sold...

Page 15: ...al dongles to create more expansion ports up to 64 units supported with the use of 20 dongles Intended for exclusive use with AC Infinity controllers with UIS ports and sold separately UIS M F 4 PORT DONGLE UIS M F 2 PORT DONGLE MOLEX ADAPTER Use the included Molex adapter to plug inline fans with 4 pin Molex connectors into this controller Plug your fan s Molex connector into the adapter Then plu...

Page 16: ...17 ADDING MORE DEVICES The CONTROLLER 69 is built with four ports that enable you to power and control multiple devices at the same time See image below for a sample configuration ...

Page 17: ...to recognize as the primary device All other devices plugged into the dongle will follow programming intended for the device plugged into Port 1 Dongles are not included and sold separately EXTENDING THE CHAIN When plugging additional dongles into Port 1 all devices plugged into this chain must be of the same type ex grow lights of any size regardless of the length of the dongle chain 1 2 3 4 1 2 ...

Page 18: ...ER alert 13 USER SETTING Displays the value of your current mode Use the up or down buttons to adjust the value 12 COUNTDOWN Displays the countdown of the TIMER TO ON TIMER TO OFF CYCLE or SCHEDULE mode activates or deactivates the devices TO ON shows the amount of time left before the devices turn on TO OFF shows the amount of time left before the device turn off 7 PROBE HUMIDITY Displays the cur...

Page 19: ...ing the ALL port will resume its programming INDIVIDUAL PORT Navigate to a numbered port with a connected device to set individual programming Programming will run in the background even while you navigate to other numbered ports PORTS Pressing the port button will cycle through the controller s available ports ALL 1 2 3 and 4 Dot indicates the current device No digit is displayed if a device is n...

Page 20: ...IMUM LEVEL Your devices will not run while in this mode The level set while in this mode establishes the minimum level in other modes When the devices are triggered to turn OFF in all other modes they will instead run at the level set here Set the level to zero if you want the device to turn off when triggered OFF CONTROLLER MODES Pressing the mode button will cycle through the controller s availa...

Page 21: ... set in OFF Mode other than zero the devices will run at that level when triggered to turn off Any of the four trigger points can activate while you are in AUTO Mode even if you are viewing another trigger point Please set a trigger point to OFF if not in use by holding down the up and down button If there is a level set in OFF Mode other than zero the devices will run at that level when triggered...

Page 22: ...ally ramp up to the level set in ON mode If the probe s reading falls below this trigger point the devices will gradually slow down to a stop or at the level set in OFF mode You may set this trigger below the low humidity trigger to create a specific range in which the devices are active Any of the four trigger points can activate while you are in AUTO Mode even if you are viewing another trigger ...

Page 23: ...set in OFF Mode other than zero the devices will run at that level when triggered to turn off PROGRAMMING TIMER TO OFF MODE Pressing the up or down button sets a countdown time The devices will run at the level set in ON Mode until the countdown ends If there is a level set in OFF Mode the devices will run at that level after the end of the countdown The countdown will begin if no buttons are pres...

Page 24: ...hey will run at the level set in ON Mode When the devices are deactivated they will run at the level set in OFF Mode The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown before the next ON or OFF phase is displayed below the current level Leaving the cycle mode while the countdown is running will pause it until you return to this mode If there is a level ...

Page 25: ...ivate they will run at the level set in ON Mode When the devices are triggered to deactivate they will run at the level set in OFF Mode The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown before the next on or off phase is displayed below the current level The devices will not follow this schedule if you leave this mode If you re enter the Schedule Mode ...

Page 26: ...rightness level at 2 and 3 respectively and will dim down the brightness level 1 when the controller is not being used after 15 seconds CONTROLLER SETTINGS Pressing the setting button will cycle through the controller s available settings DISPLAY F C CLOCK CALIB T CALIB H TRANS T and TRANS H TOGGLING THE DISPLAY Lock the controller by holding the setting button Press the setting button to turn the...

Page 27: ...cle through 12 00 each time the units will automatically change to AM or PM The clock time is located at the top right corner of the display F C SETTING Changes the displayed units to Fahrenheit or Celsius Press the up or down button to cycle through F and C All displayed units will automatically convert when adjusting this setting ...

Page 28: ...he calibration cycle ranges from 20 F to 20 F or 10 C to 10 C and will be applied to the sensor probe s measurements CALIBRATION HUMIDITY SETTING Adjusts the relative humidity reading the sensor probe is measuring Press the up or down button to increase or decrease the data figure in 1 increments The calibration cycle ranges from 10 to 10 and will be applied to the sensor probe s measurements ...

Page 29: ...or down button to cycle through 0 F to 8 F 0 C to 4 C and set a transition threshold The level will be set one level above the OFF Mode level when the sensor temperature first meets or exceeds the high temperature trigger For every transition threshold crossed the level will ramp up by one level up until it reaches the level set in ON Mode In this example your high temperature trigger is set at 80...

Page 30: ...ss the up or down button to cycle through 0 to 8 to set a transition threshold The level will be set one level above the OFF Mode level when the sensor humidity first meets or exceeds the high humidity trigger For every transition threshold crossed the level will ramp up by one level up until it reaches the level set in ON Mode In this example your high humidity trigger is set at 67 the OFF Mode l...

Page 31: ...GRAMMING Displays when an advance program set in the app is active ADV will appear and override the controller if an automation program is in use AUTO MODE ALERT Flashes whenever any of the auto mode triggers high temperature low temperature high humidity or low humidity activate your devices TIMER ALERT Flashes when a countdown has completed for TIMER TO ON TIMER TO OFF CYCLE or SCHEDULE Mode ...

Page 32: ...mperature humidity meet the trigger point set in the app DISPLAY LOCK ALERT Displays when you lock the controller The icon will flash and beep if you attempt to adjust the controller while it is still locked WIFI Appears when the physical controller is connected to the app via WiFi ...

Page 33: ... shown MINIMUM LEVEL You can set a minimum level for the device to continuously run at until it s triggered ON This can be set in OFF MODE The level you leave that mode in will be used as the minimum level for all other modes such as AUTO MODE CYCLE MODE TIMER TO ON MODE TIMER TO OFF MODE and SCHEDULE MODE They will run at the level set here even when they are triggered to be OFF They will continu...

Page 34: ...or will you be able to switch modes Holding the setting button again will unlock the controller HOLD HIDE SCREEN Lock the controller so no settings can be adjusted See above Then press the setting button to turn the display off Pressing it again will turn the display back on Programs will still run in the background while the LCD screen is off PRESS RESET TO OFF DEFAULT Holding the up and down but...

Page 35: ... data Download the AC Infinity app from the App Store or Play Store by searching AC Infinity Open the AC Infinity app and follow the instructions on page 37 38 to pair your controller with the app Visit our website at www acinfinity com or open your smartphone camera and scan the QR code below for more information on the AC Infinity app HOW TO USE THE APP Appearance and features subject to change ...

Page 36: ... the pairing process SETUP AND PAIRING Power your device on before pairing your controller with the app Logging in or creating an account beforehand will expedite the pairing process Have your WiFi network s name and password ready 1 Tap on the tab to add your smart device 2 Select Smart Controllers ...

Page 37: ...38 ADD A DEVICE Select CONTROLLER 69 WIFI Log in or create an account to continue 3 4 ...

Page 38: ...it for the WiFi icon to start flashing on your controller s screen to release the button The app will search for and pair with the controller you have activated When pairing the app around multiple controllers move your mobile device closer to your desired controller 6 5 ...

Page 39: ...ay also connect to an alternate 2 4GHz router Follow these tips if the pairing process is unsuccessful This controller is only compatible with 2 4 GHz frequency band routers Make sure your mobile device is not connected to a 5 GHz frequency band network 7 8 ...

Page 40: ...41 ADD A DEVICE Tap the DONE button to complete the pairing process Your controller will appear in your smart device with a unique ID DONE 9 10 E E000E ...

Page 41: ...re set in OFF Mode determines the device s level when it s triggered to be OFF in all other modes Set that figure to zero if you want the device to turn off when triggered OFF If this is occurring in AUTO Mode please check your high and low triggers point which can all activate concurrently Turn off any trigger points that are not in use If you are using the app please check if you have any ADVANC...

Page 42: ...int the device will increase by one level The lower the transition threshold is set to the easier it will be for the device to ramp up in levels If set to zero the device will jump to the max set speed without ramping when triggered This may cause the device to turn on and off quickly if the climate fluctuates back and forth Increase the transition threshold number to help smooth out the transitio...

Page 43: ...quires location permissions to find the relative position of your smart controller and communicate with existing Bluetooth devices already paired with the app All Android devices prior to system version 12 0 will require location permissions to be turned on for the Bluetooth scan to be successful Q Will I be able to use this controller with my own fan A The CONTROLLER 69 WIFI is only compatible wi...

Page 44: ...late to install your AC Infinity controller onto Inline Duct Fans The CLOUDLINE series is a line of duct fans designed to quietly ventilate AV rooms and closets as well as various DIY air circulation and exhaust projects Features a thermal controller with intelligent programming that will automatically adjust duct fan speeds in response to changing temperatures Grow Lights An indoor LED grow lamp ...

Page 45: ...he date of purchase The program will expire two years from the date of purchase If your product becomes defective during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product in water incorrect Installation such as wrong voltage input and misuse for any ...

Page 46: ...sonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful int...