background image

SMART OUTLET

ENVIRONMENTALLY CONTROLLED

USER MANUAL

Summary of Contents for CONTROLLER 75

Page 1: ...SMART OUTLET ENVIRONMENTALLY CONTROLLED USER MANUAL ...

Page 2: ......

Page 3: ...roduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL support acinfinity com WEB www acinfinity com LOCATION Los Angeles CA ...

Page 4: ...4 PRODUCT CONTROLLER 79 CONTROLLER 75 MODEL CTR79A CTR75A UPC A 819137023680 819137022508 MANUAL CODE SOT2207X1 ...

Page 5: ... MH and HPS Lights Key Features Product Contents Powering and Setup Programming Other Settings Download the App Add a Device FAQ Other AC Infinity Products Warranty Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 13 Page 33 Page 34 Page 35 Page 38 Page 40 Page 41 ...

Page 6: ...s product s installation seek the services of a qualified trained and licensed professional Inappropriate installation will void this product s warranty This product must not be used in potentially hazardous locations such as flammable explosive chemical laden or wet atmospheres Do not cover power cords with rugs or other fabric materials Do not depend on the on off programming as the sole means o...

Page 7: ...proper functionality and to prevent radio frequency interference from affecting your sensor probe TIP 1 Keep the probe cord far away from your ballast s cords to ensure the controller properly detects climate conditions You may also wrap the probe cord and create a cone around the sensor head with aluminum foil tape TIP 2 Do NOT plug your grow light and inline fan into the same duplex outlet Plug ...

Page 8: ...LER Features automation controls that power devices based on temperature humidity timers and schedules DUAL OUTLETS Built with a detached electrical socket module that allows for powering and controlling two devices at the same time SENSOR PROBE Corded probe made of stainless steel to ensure precise temperature and humidity readings EXTRA CORD LENGTH Extended cord length of 144 inches 12 feet for ...

Page 9: ...CONTENTS WALL HANG CONTROLLER x1 WALL HANG WOOD SCREWS x2 SENSOR PROBE x1 WIRE TIE x1 CABLE TIE MOUNT x1 DESKTOP CONTROLLER x1 WALL HANG WOOD SCREWS x2 SENSOR PROBE x1 WIRE TIE x1 CABLE TIE MOUNT x1 CTR79A CTR75A ...

Page 10: ...10 POWERING AND SETUP STEP 1 Plug the sensor probe into the 3 5mm port located at the bottom side of your controller STEP 2 Insert the power plug into a wall outlet to power your controller ...

Page 11: ...ETUP STEP 3 Position the corded sensor probe and secure it by using the included zip ties and tie mounts STEP 4 Locate a spot free of obstruction and secure the anchor into your wall Twist the wood screw into the anchor ...

Page 12: ...12 POWERING AND SETUP STEP 6 Plug your device not included into one of the two sockets to power it with your controller STEP 5 Hang your controller by the screw using the hole located on its backside ...

Page 13: ...triggers TIMER TO ON TIMER TO OFF CYCLE On and Off and SCHEDULE On and Off 4 SETTING BUTTON Cycles through each of the controller s settings DISPLAY BRIGHTNESS F C CLOCK CALIBRATION Temperature and Humidity and BUFFER Temperature and Humidity 3 UP DOWN BUTTONS Adjusts the value of your current mode The up button increases and down button decreases the setting Hold both to reset values to OFF or 0 ...

Page 14: ...ing powered and OFF will display if your devices are not being powered 8 CONTROLLER MODE Displays the controller s current mode Pressing the mode button cycles through the available modes 9 STATUS ICONS Flashes or displays the alert icons of the controller The icons include TIMER ALERT and DISPLAY LOCK 10 CURRENT TIME Displays the current time The internal battery sustains the clock so it does not...

Page 15: ...you navigate to other outlets Re entering the ALL outlet will resume its programming INDIVIDUAL OUTLET Navigate to a numbered outlet with a plugged in device to set individual programming Programming will run in the background even while you navigate to other numbered outlets OUTLETS Pressing the outlet button will cycle through the controller s available outlets ALL 1 and 2 Dot indicates the curr...

Page 16: ...N TIMER TO OFF CYCLE On and Off and SCHEDULE On and Off ON MODE Your device will stay on regardless of temperature humidity or time based triggers OFF MODE Your device will remain off regardless of temperature humidity or time based triggers Jump back to OFF Mode anytime by holding the MODE button while in other modes or settings PROGRAMMING ...

Page 17: ...ture when it gets too hot For example if you set a high temperature trigger of 90 F then your device will activate when the temperature reaches 90 F or higher and turn off when it falls below 90 F Products shown here may still be in development Note that any of the four AUTO Mode triggers can activate at the same time even if you are not viewing that specific trigger Turn off any triggers not in u...

Page 18: ...e when it gets too cold For example if you set a low temperature trigger of 40 F then your device will activate when the temperature falls to 40 F or lower and turn off when it rises above 40 F Products shown here may still be in development PROGRAMMING Note that any of the four AUTO Mode triggers can activate at the same time even if you are not viewing that specific trigger Turn off any triggers...

Page 19: ...gets too humid For example if you set a high humidity trigger of 70 then your device will activate when the humidity rises to 70 or higher and turn off when it falls below 70 Products shown here may still be in development PROGRAMMING Note that any of the four AUTO Mode triggers can activate at the same time even if you are not viewing that specific trigger Turn off any triggers not in use by pres...

Page 20: ...midity when it gets too dry For example if you set a low humidity trigger of 50 then your device will activate when the humidity falls to 50 or lower and turn off when it rises above 50 Products shown here may still be in development Note that any of the four AUTO Mode triggers can activate at the same time even if you are not viewing that specific trigger Turn off any triggers not in use by press...

Page 21: ...ntil you return to this mode TIMER TO ON MODE Pressing the up or down button sets a countdown time During the countdown your device will be set to OFF Once the timer ends your device will trigger to turn on The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown is shown on the lower right corner of the display above the setting Leaving the timer mode while ...

Page 22: ...untdown for your device to turn on Then press the mode button and use the up or down button to set a countdown for your device to turn off The countdown will begin if no buttons are pressed for 5 seconds Leaving the CYCLE mode while the countdown is running will pause it until you return to this mode PROGRAMMING 30min 1hr 30min 1hr O F F ON ON O F F ...

Page 23: ...r your device to turn off The countdown will begin if no buttons are pressed for 5 seconds The time left on the countdown before the next ON or OFF phase is shown on the lower right corner of the display above the setting Your device will not follow this schedule if you leave this mode If you re enter the schedule mode it will continue to follow the latest schedule you have set PROGRAMMING ON AM O...

Page 24: ...ightness level at 2 and 3 respectively and will dim down the brightness level 1 when the controller is not being used after 15 seconds CONTROLLER SETTINGS Pressing the setting button will cycle through the controller s available settings DISPLAY F C CLOCK CALIB T CALIB H BUFFER T and BUFFER H TOGGLING THE DISPLAY Lock the controller by holding the setting button Press the setting button to turn th...

Page 25: ...12 00 each time the units will automatically change to AM or PM The clock time is located at the lower left corner of the display PROGRAMMING F C SETTING Changes the displayed units to Fahrenheit or Celsius Press the up or down button to cycle through F and C All displayed units will automatically convert when adjusting this setting ...

Page 26: ...tion cycle ranges from 20 F to 20 F or 10 C to 10 C and will be applied to the sensor probe s measurements CALIBRATION HUMIDITY SETTING Adjusts the relative humidity reading the sensor probe is measuring Press the up or down button to increase or decrease the data figure by 1 increments The calibration cycle ranges from 10 to 10 and will be applied to the sensor probe s measurements PROGRAMMING ...

Page 27: ...Temperature Buffer of 6 F BUFFER SETTING This setting modifies AUTO Mode programming by creating a buffer for temperature and humidity triggers This sets a different trigger off point for the triggers generating an on and off band that prevents the device from triggering too quickly from small climate fluctuations You can set a buffer figure for temperature triggers and a buffer figure for humidit...

Page 28: ...point For example if you had set the Low Temperature Trigger at 50 F and set the Temperature Buffer at 4 F Then your device will trigger on when it meets or falls below 50 F and only trigger off when it rises above 54 F The 54 F figure is obtained by taking your Low Temperature Trigger of 50 F and adding your temperature buffer of 4 F PROGRAMMING ...

Page 29: ...low your set trigger point For example if you had set a High Humidity Trigger at 70 and set a Humidity Buffer at 4 Then your device will trigger on when it meets or rises above 70 and only trigger off when it falls below 66 The 66 figure is obtained by taking your High Humidity Trigger of 70 and subtracting your Humidity Buffer of 4 ...

Page 30: ...t trigger point For example if you had set the Low Buffer Trigger at 40 and set the Humidity Buffer at 6 Then your device will trigger on when it meets or falls below 40 and only trigger off when it rises above 46 The 46 F figure is obtained by taking your Low Humidity Trigger of 40 and adding your humidity buffer of 6 PROGRAMMING ...

Page 31: ...VANCE PROGRAMMING Displays when an advance program set in the app is active ADV will appear and override the controller if an automation program is in use AUTO MODE ALERT Flashes whenever any of the auto mode triggers high temperature low temperature high humidity or low humidity activate your devices TIMER ALERT Flashes when a countdown has completed for TIMER TO ON TIMER TO OFF CYCLE or SCHEDULE...

Page 32: ... flash and beep if you attempt to adjust the controller while it is still locked TEMPERATURE HUMIDITY ALARM Flashes and beeps with alarm if the temperature humidity meet the trigger point set in the app BLUETOOTH Appears when the physical controller is connected to the app via Bluetooth ...

Page 33: ...utton to turn the display off Pressing it again will turn the display back on Programs will still run in the background while the LCD screen is off PRESS RESET TO OFF DEFAULT Holding the up and down buttons together for 2 seconds will reset the value of your current mode or controller setting to OFF Default Pressing either the up or down button will return to the previous value HOLD HOLD AUTO INCR...

Page 34: ... data Download the AC Infinity app from the App Store or Play Store by searching AC Infinity Open the AC Infinity app and follow the instructions on page 35 37 to pair your controller with the app Visit our website at www acinfinity com or open your smartphone camera and scan the QR code below for more information on the AC Infinity app HOW TO USE THE APP Appearance and features subject to change ...

Page 35: ...n the Smart Outlets tab to begin pairing Please note Bluetooth must be enabled on your mobile device before starting the pairing process SETUP AND PAIRING Power your device on before pairing your device with the app Refer to pages 10 12 for more information regarding controller setup ...

Page 36: ...36 ADD A DEVICE Hold the port button for 5 seconds to activate Bluetooth Wait for the Bluetooth icon to start flashing on your controller s screen Select CONTROLLER 79 to begin pairing 3 4 ...

Page 37: ...to complete the pairing process Your controller will appear in your smart device with a unique ID Please note When pairing the app around multiple controllers move your mobile device closer to your desired controller DONE B B000B 5 6 ...

Page 38: ... spot in your space Q Do I need to remove the plastic cap from the probe A Yes You will need to remove the plastic cap so the probe can accurately read climate conditions Q Will I be able to use this controller with my own fan A Yes This controller can be used with any fan with Type A or Type B AC power plugs Q Does the controller retain its settings after power is shut off A Yes If the controller...

Page 39: ... off any trigger points that are not in use FAQ Q Why is my humidifier not turning on or off when I programmed it to do so under AUTO mode A If this is occurring in AUTO mode for humidity triggers please note that the HIGH HUMIDITY trigger turns the device ON when the humidity number you have set is exceeded If you want the device to turn OFF when the humidity number you have set is exceeded pleas...

Page 40: ... duct boosting designed to improve airflow in heating and air conditioning applications and ventilate home rooms like attics workshops bathrooms and kitchens Each fan uses an easy to use knob controller that adjusts fan speed for your specific airflow boosting needs Axial Fans The AXIAL series fan kit is designed for various DIY projects that requires cooling or ventilation or as a replacement fan...

Page 41: ...e during that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the product in water incorrect Installation such as wrong voltage input and misuse for any reason other than intended purposes AC Infinity is not responsible for consequential loss or incidental damages ...

Page 42: ... part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without specific permission from AC Infinity Inc ...

Page 43: ......

Page 44: ...www acinfinity com ...

Reviews: