background image

37

AC INFINITY PRODUCTS

Discover the latest innovations in environmental controls at acinfinity.com

Advance Grow Tents

The CLOUDLAB series is a line of grow tents designed to create 
ideal growing conditions and facilitate indoor plant cultivation 
year-round. Features 2000D thick oxford canvas lined with inner 
diamond-patterned mylar that maximizes grow light luminosity, and 
a reinforced frame with 150 lb. weight capacity. Includes a mounting 
plate to install your AC Infinity controller onto.

Thermo-Hygrometers

The CLOUDCOM series is a line of smart thermo-hygrometers 
designed to accurately detect and measure your space's temperature 
and relative humidity. Features a bright backlit screen and desktop, 
wall, or magnetic mounting options to place and display anywhere. 
Select models include a corded, Swiss-made sensor probe by 
Sensirion AG for spot detection.

CONTROLLER 69 PRO

The CONTROLLER 69 PRO is the centerpiece of the UIS platform, 
able to connect with our smart devices including fans and LED grow 
lights to create the optimal growing environment. Connects with up 
to four devices to provide independent programming while capable 
of dynamically adjusting fan speed and brightness intensity levels in 
response to temperature, humidity, and VPD levels.

Summary of Contents for CLOUDFORGE

Page 1: ...1 USER MANUAL CLOUDFORGE ENVIRONMENTAL HUMIDIFIER...

Page 2: ......

Page 3: ...oduct quality and friendly customer service If you have any questions or suggestions please don t hesitate to contact us Visit www acinfinity com and click contact for our contact information EMAIL su...

Page 4: ...4 MANUAL CODE CF2311X1 MODEL AC CFT3 AC CFT5 AC CFT7 AC CFT9 PRODUCT CLOUDFORGE T3 CLOUDFORGE T5 CLOUDFORGE T7 CLOUDFORGE T9 UPC A 819137023611 819137023635 819137023628 819137023642...

Page 5: ...uct Contents Installation Powering and Setup UISTM Platform Connecting to UIS Controllers Cleaning Programming Other Settings Other AC Infinity Products Warranty Page 5 Page 6 Page 7 Page 8 Page 9 Pag...

Page 6: ...in potentially hazardous locations such as flammable explosive electrical or chemical laden atmospheres Do not cover any power cords with rugs or other fabric materials Safety precautions should be ex...

Page 7: ...roller with LED touch interface featuring humidity balance programming Pair with UIS controllers to access intelligent programming and app control with advance automation and data charts PRECISION DET...

Page 8: ...1 FLEXIBLE HOSE x1 CLOUDFORGE T7 ALL MODELS PROBE MOUNT x1 NEBULIZER BRUSH x1 HOOK AND LOOP TIE x1 UIS EXTENSION CORD M M x1 SENSOR PROBE x1 15L HUMIDIFIER x1 5 WAY NOZZLE x1 ELBOW NOZZLE x1 PIPE BASE...

Page 9: ...into the tank You may detach the tank to fill it with water We recommend using distilled water to reduce the amount of mineral build up NOTE Do NOT pour water into the central pipe This will prevent...

Page 10: ...10 INSTALLATION CLOUDFORGE T3 STEP 2 You may swap the directional flow cap with the included flexible hose for extended targeted flow 1 2...

Page 11: ...o result in water flowing back into the base which can overflow it and cause leakage In addition make sure the hose is sloped upwards when routing it to your grow tent Sloping the hose downward will r...

Page 12: ...into the tank You may detach the tank to fill it with water We recommend using distilled water to reduce the amount of mineral build up 1 2 NOTE Do NOT pour water into the central pipe This will prev...

Page 13: ...flow 5 way nozzle for omnidirectional flow Make sure the elbow nozzle is placed over the pipe with the interior ridge facing the ground OR INSTALLATION CLOUDFORGE T7 STEP 2 Top the center lid opening...

Page 14: ...STALLATION CLOUDFORGE T7 USING YOUR OWN PIPES You may use your own PVC pipes to extend the reach of your humidifier Line the pipe with the included elastic band and attach it to the base or elbow nozz...

Page 15: ...idity from emitting This will also result in water flowing back into the base which can overflow it and cause leakage Dry the hose after each use In addition make sure the hose is sloped upwards when...

Page 16: ...CLOUDFORGE T3 STEP 1 Plug the sensor connector with the gasket into the 3 5mm jack located at the rear side The gasket is specially designed to protect against liquids and dust Route the probe head to...

Page 17: ...n cord into the rear side port to connect your humidifier to your UIS controller Plug the UIS connector with the gasket end into your humidifier The gasket is specially designed to protect against liq...

Page 18: ...ector with the gasket into the 3 5mm jack located below the display screen The gasket is specially designed to protect against liquids and dust Route the probe head to spot areas as needed You may als...

Page 19: ...an outlet to power it STEP 2 You may plug the included UIS extension cord into the front side port to connect your humidifier to your UIS controller Plug the UIS connector with the gasket end into you...

Page 20: ...t Your grow system can be regulated using your controller hub or remotely on the AC Infinity app paired with compatible controllers where you will have access to automation programming and climate dat...

Page 21: ...specially designed to protect against liquids and dust Your CONTROLLER 69 PRO unit will override all on board settings assume control parameters must be adjusted on CONTROLLER 69 PRO and shut off your...

Page 22: ...it sit for five minutes Exchange the water in the reservoir at least once every 4 days Clean and maintain your humidifier and its filter piece at least once a week The filter piece is used to catch an...

Page 23: ...om the tank and soak it in two cups of distilled water and one tablespoon of vinegar for 5 minutes STEP 4 Pour out the vinegar water mixture and wipe the base dry Replace the tank to finish STEP 3 Use...

Page 24: ...The up button increases and down button decreases the setting Hold both to reset values to OFF Default 5 PROBE HUMIDITY Displays the current humidity that the probe is measuring Shows if no probe is p...

Page 25: ...el the other modes will run at while triggered OFF MINIMUM LEVEL Your humidifier will run at the level set in OFF Mode as the minimum level when triggered to turn OFF These other modes include the AUT...

Page 26: ...Mode CYCLE Mode and TIMER Mode Do not set the ON Mode figure to zero or your humidifier will turn off when it s triggered ON in all modes ON MODE Your humidifier will actively run at the level set her...

Page 27: ...t in ON Mode If the probe s reading rises above this trigger point your humidifier will stop emitting vapors Leaving the AUTO Mode while it is active will pause it until you return to this mode PROGRA...

Page 28: ...ggered your humidifier will gradually ramp up to the level set in ON Mode If the probe s reading falls below this trigger point your humidifier will gradually slow down to a stop or at the level set i...

Page 29: ...f no buttons are tapped for 3 seconds Leaving the TIMER Mode while the countdown is running will pause it until you return to this mode PROGRAMMING START TIMER TO OFF COUNTDOWN END POINT 0 m i n to OF...

Page 30: ...your humidifier is activated it will run at the level set in ON Mode When your humidifier is deactivated it will run at the level set in OFF Mode The countdown will begin if no buttons are pressed fo...

Page 31: ...cycle through F and C All displayed units will automatically convert when adjusting this setting Screen shown CLOUDFORGE T3 CALIBRATION TEMPERATURE SETTING Adjusts the temperature reading the sensor...

Page 32: ...ranges from 10 to 10 and will be applied to the sensor probe s measurements CALIBRATION LEAF OFFSET SETTING Adjusts the VPD reading the sensor probe is measuring Press the up or down button to increas...

Page 33: ...SAFE Displays whenever your humidifier falls or is tilted past a 20 angle Your humidifier will pause programming and its screen will flash until it is back to an upright position WATER LEVEL LOW Disp...

Page 34: ...icon will flash and beep if you attempt to adjust your humidifier while it is still locked VPD ALERT Flashes whenever the VPD Mode trigger activates your humidifier TIMER ALERT Flashes when a countdo...

Page 35: ...etting will automatically jump to OFF Mode This function is disabled if the humidifier is locked HOLD CONTROLLER LOCK Holding the setting button will lock the humidifier in your current mode While you...

Page 36: ...buttons again will re enable them HOLD AUTO INCREASING OR DECREASING Holding the up or down button will increase or decrease the user setting automatically until you release them HOLD RESET TO OFF DE...

Page 37: ...ries is a line of smart thermo hygrometers designed to accurately detect and measure your space s temperature and relative humidity Features a bright backlit screen and desktop wall or magnetic mounti...

Page 38: ...uring that period AC Infinity will replace your product with a new one or issue you a full refund The warranty program does not cover abuse or misuse This includes physical damage submersion of the pr...

Page 39: ...part of the materials including graphics or logos available in this booklet may be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in...

Page 40: ......

Page 41: ......

Page 42: ......

Page 43: ......

Page 44: ...www acinfinity com...

Reviews: