PROGRAMMING
T-SERIES
OFF MODE
Your fan will not run while in this mode. Use the up
and down buttons to adjust the backlight brightness.
Setting the brightness to the auto-dim level (1st
and 3rd bars illuminated) will dim the display to the
lowest setting whenever the controller is not being
used after 30 seconds.
SMART MODE
Sets the transition threshold between fan speed
levels. Use the up and down buttons to adjust the
SETTING temperature.
1.
Set a maximum fan speed in ON Mode.
2.
Multiply this speed by the variation buffer (ex. 4°F).
3.
Add the result from step 2 to your desired
trigger point. Subtract your buffer setting (ex. 4°F)
from this figure.
4.
Set the result from step 3 as your
SETTING temperature.
For example, ([ON mode speed =
6
] x [variation
buffer =
4°F
]) + [desired temperature trigger =
85°F
] -
[variation buffer =
4°F
] = [SETTING temperature
=
105°F
]
ALARM
SETTING
F
o
F
o
PROBE
F
o
ALARM
SETTING
F
o
F
o
PROBE
F
o
See page 25 to learn how to adjust the
variation buffer.
Buffer = 4°F
+4°F
85°F
89°F
93°F
97°F
101°F
105°F
+4°F
+4°F
+4°F
+4°F
Setting Temp.
Desired Trigger Point
23
Summary of Contents for AIRPLATE Series
Page 1: ...1 AIRPLATE SERIES USER MANUAL CABINET COOLING SYSTEM...
Page 2: ...2...
Page 34: ......
Page 35: ......
Page 36: ...www acinfinity com...