PROGRAMMING
T-SERIES
VARIATION BUFFER
Adjusts the gap from your SETTING temperature to prevent the fans from shutting off too quickly
due to fluctuating change in the environment. This setting toggles between 4°F (2°C) and 2°F (1°C)
buffers.
Hold the MODE button and DOWN button together for 3 seconds to change the variation buffer to
2°F (1°C).
Hold the MODE button and UP button together for 3 seconds to change the variation buffer back to
4°F (2°C).
In AUTO Mode, the PROBE temperature will need to fall at least 4°F (2°C) or 2°F (1°C) for the fans
to stop running. Fans will still immediately run when the PROBE temperature meets or exceeds the
SETTING temperature.
In SMART mode, the fan speed will lower by one level for every 4°F (2°C) or 2°F (1°C) the PROBE
temperature is below the SETTING temperature.
CONTROLLER LOCK
Toggles the controller lock. Hold the MODE button for 3 seconds to lock controller. Programs
will still run in the background while the controller is locked, but pressing a button will cause the
screen lock icon to flash instead.
Hold the MODE button again for three seconds to unlock the controller.
25