Electrical connection:
The
Abyzz A100
requires a connection of 90...230V/50...60Hz.
The component must be connected to a suitable, properly installed earthed wall
socket that is fused with a circuit breaker as per DIN VDE 0100T739 (residual
current circuit breaker). We recommend that you do not connect more than 4
controllers to a supply line (16A fuse). The product has a mains switch, which is
located on the connector element. The IEC connector on the Abyzz mains cable
has a lock to prevent it from falling out. Press the red lock/unlock button on the IEC
plug (fig. 1b) and then pull out the plug.
Fig. 1:
Connector view of driver
Installation of pump
The
Abyzz
pump can be immersed to a depth of 2 metres or installed in a dry
position, both either horizontally or with outlets down.
On the intake side, make sure that the water can flow in freely and protect the
intake by means of a screen suitable for keeping coarse particles, sand, filter
cotton fibres etc.) away from the impeller wheel. When laying the piping, make
sure that there is at least 20cm of straight pipe on the intake side to allow the
water to enter on a straight course. This measurement optimizes the product's
efficiency and significantly reduces noise. For even more efficiency, use sufficient
pipe diameters for large pipe systems (recommended: 63mm on the intake side,
50mm on the pressure side).
When using adhesive fittings, use an adhesive suitable for ABS and PVC.
12