wAppLoxx Pro Control Complete Instructions
Type:
You can use the “Type” option to change the input processing method.
High:
If 12
V are applied at the input, the alarm panel is ready for “arming”.
High:
If 0 V are applied at the input, the alarm panel is
not ready for “arming”.
Low:
If 12
V are applied at the input, the alarm panel is not ready for “arming”.
Low:
If 0
V are applied at the input, the alarm panel is ready for “arming”.
Status:
If this option is checked, then this input is active.
Arm Input:
You can use the Arm Input to switch between “arming” and “disarming” the wAppLoxx Pro
Control for a connected alarm panel. Each time the connected alarm panel switches between
its “armed” and “disarmed” status, the wAppLoxx Pro Control is also switched between
“armed” and “disarmed” accordingly. This ensures that the connected alarm panel and the
wAppLoxx Pro Control have the same status. Input 2 is used by default (see Chapter 3).
Delay:
Select a delay time of between 10 and 20 seconds. The delay time defines how long the alarm
panel has to wait.
Type:
You can use the “Type” option to change the input processing method.
High:
If 12
V are applied at the input, the wAppLoxx Pro Control is “armed”.
High:
If 0 V are applied at the input, the wAppLoxx
Pro Control is “disarmed”.
Low:
If 12
V are applied at the input, the wAppLoxx Pro Control is “disarmed”.
Low:
If 0
V are applied at the input, the wAppLoxx Pro Control is “armed”.
Status:
If this option is checked, then this input is active.
Alarm input:
An alarm is signalled via the alarm input for the wAppLoxx Pro Control.
Input 3 is used by default (see Chapter 3).