Abus wAppLoxx Pro Installation And Operating Instructions Manual Download Page 30

 

[30] 

wAppLoxx Pro Control Complete Instructions 

 

6.3 Notifications 

 

 

 

An email account from an email provider (such as GMX) is required to enable email 

notifications. You can use an existing account or create an new one for your Control.  

 

You can obtain the necessary server addresses and ports from your email 

provider. 

 

Sender:

 

 

 

Sender name for the wAppLoxx Pro Control

 

Sender email address:

 

The email address associated with the sender

 

SMTP server:

  

 

SMTP server address of the provider

 

Port: 

 

 

 

Enter the SMTP port/standard port: 25 

SSL:

 

 

Check this box to activate the email encryption.

 

User name:

 

 

 

User name for the email address

 

Password:

 

 

 

Password for the email address

 

Recipient email: 

 

Email address of the recipient 

Test the notification 

 

Clicking on “Send” prompts the wAppLoxx Pro 

email: 

Control to send a test email to the first recipient entered. 

 

 

Summary of Contents for wAppLoxx Pro

Page 1: ...1 wAppLoxx Pro Control Complete Instructions Installation and operating instructions wAppLoxx Pro Control WLX Pro CTRL...

Page 2: ...AppLoxx Pro Control 20 5 4 Creating users 21 5 5 Creating user groups 21 5 6 Creating door groups 23 5 7 Locking plan 24 5 8 Activating the web connection 25 6 Advanced configuration 27 6 1 Date and T...

Page 3: ...3 wAppLoxx Pro Control Complete Instructions 10 5 Remote event 70 11 User interface 72 11 1 Remote functions 73 11 2 Protocol event log 74 12 Conditions of use for wAppLoxx 76...

Page 4: ...t with the electronics should also be avoided ABUS Security Center GmbH Co KG shall not be held liable for loss or damage caused or alleged to have been caused either directly or indirectly by this ma...

Page 5: ...ry s specific regulations Information on the wireless range The wireless range between the wAppLoxx Pro Cylinder and the wAppLoxx Pro Control is largely dependent on the individual local conditions pa...

Page 6: ...second time the notification should no longer appear To ensure a long lifespan and safe operation we recommend using the following high quality batteries wAppLoxx Pro Cylinder Duracell Ultra or Varta...

Page 7: ...al Exterior dimensions 165 160 28 mm H B T Material White plastic housing Tags max 500 Door systems max 32 per CTRL Pro Configuration Web interface web browser platform independent Functions Optional...

Page 8: ...trol Screw the enclosed external antennas onto the connections provided for this purpose and mount the housing using four screws Make sure there is sufficient spacing approx 1 m to the ceiling and wal...

Page 9: ...ework of CE approval we recommend only using the original ABUS power supply unit Item no AZZU10010 AZZU10011 We recommend switching to a new original ABUS power supply unit particularly in the event o...

Page 10: ...signalling System power consistent green System in update mode or restarting flashing blue Wireless communication between the wAppLoxx Pro Control and wAppLoxx Pro Cylinder blue during wireless commu...

Page 11: ...ng the wAppLoxx Pro Control directly to a PC laptop 1 Connect the wAppLoxx Pro Control to your PC laptop via a network cable 2 Connect the wAppLoxx Pro Control to the power supply The wAppLoxx Pro Con...

Page 12: ...Your wAppLoxx Pro Control will now appear under local devices s Recommended configuration We recommend configuring the wAppLoxx Pro Control using the wAppLoxx Pro Control Finder Recommended web brows...

Page 13: ...ault on delivery User name administrator Password 12345678 Important Please ensure you change the administrator access after initial commissioning Keep the password for administrator access safe Shoul...

Page 14: ...0 50 In this case first configure your router switch and PC laptop as follows Router Switch IP address 192 168 0 1 Subnet mask 255 255 255 0 PC laptop IP address 192 168 0 2 Subnet mask 255 255 255 0...

Page 15: ...g the wAppLoxx Control Finder Recommended web browser Use the latest version of Mozilla Firefox or Google Chrome to carry out programming Alternatively Internet Explorer version 11 306 or above or Edg...

Page 16: ...ory reset is carried out Make sure you secure the data through regular backups Initial start up After logging in for the first time a pop up window will appear asking you to select your language setti...

Page 17: ...oint you will be asked to do so again each time you log in 5 Quick configuration On the overview page of the main menu you can find an overview of all the important information about your wAppLoxx Pro...

Page 18: ...pLoxx Pro Cylinder does not have a mechanical reset button the cylinder is set to programming or unpairing mode by presenting the system card The system card can be used for any wAppLoxx Pro Cylinder...

Page 19: ...6 and 12 seconds for the wAppLoxx Pro Cylinder Arm disarm Check this box to assign permissions for arming disarming the alarm system to the cylinder This function is only available for Intrusion cyli...

Page 20: ...a tag Programming the reset card 1 You can program the enclosed reset card under the system settings in the System access menu item Click on Program reset card 2 Then present the enclosed reset card t...

Page 21: ...can describe the respective tag as free text in this field e g the printed number of the medium Web access Assign a user name and password to the user with which they can log in to the user menu via t...

Page 22: ...u have created one or several schedules you can assign the respective schedule to the user group If you do not use schedules select the field Not used Holiday schedule If you have defined holiday sche...

Page 23: ...n boxes to assign the respective doors wAppLoxx Pro Cylinders to the door group Certain doors can be found more quickly through the search function Superordinate group The respective door group can be...

Page 24: ...relevant checkbox The following selection options appear when you click on one of the checkboxes Grant general permission Access authorisation is granted for the selected door group and its subordina...

Page 25: ...the door group only have access authorisation for the Office 1 door 5 8 Activating the web connection Activating the web connection for the wAppLoxx Pro app The wAppLoxx Pro Control must be connected...

Page 26: ...s the successful activation 6 You can now connect to your wAppLoxx Pro Control via the wAppLoxx app Use the QR code scan function on your app under menu item Add manually The QR code can be scanned vi...

Page 27: ...plete Instructions 6 Advanced configuration It is essential to configure the date and time to ensure the device functions correctly Please ensure you change the administrator access after initial comm...

Page 28: ...ny we recommend the NTP server ptbtime1 ptb de Update Interval Select an interval in which the time is synchronised via the NTP Server The wAppLoxx Pro Control must have access to the internet for thi...

Page 29: ...ng Log view settings Selecting the two man rule means the event log can only be accessed when a second user is registered in the log menu The two man rule only functions with access via the website It...

Page 30: ...nder Sender name for the wAppLoxx Pro Control Sender email address The email address associated with the sender SMTP server SMTP server address of the provider Port Enter the SMTP port standard port 2...

Page 31: ...ter If no DHCP function is available you can enter the connection data manually Contact your network administrator for assistance if necessary IP address IP address of the wAppLoxx Pro Control IPv6 mo...

Page 32: ...ther you would also like to enable the HTTP protocol For security reasons we recommend only authorising access via the HTTPS port This ensures that only secured connections can be established and the...

Page 33: ...pdate and restarts the wAppLoxx Pro Control The wAppLoxx Pro Control must not be disconnected from the power supply during the update process To restart the wAppLoxx Pro Control select the Restart but...

Page 34: ...em to another wAppLoxx Pro Control you can export them to a configuration file conf This file contains all settings with the exception of the wAppLoxx Cylinder These must be registered again from scra...

Page 35: ...the master and slave control are required for smooth operation 1 Connect both wAppLoxx Pro Controls to your network establish the power supply and connect to both controls using the wAppLoxx Pro Find...

Page 36: ...Pro Control as a master and add a slave control tick the Activate Master Only checkbox in the System settings System access menu item 8 Now tick the IP1 checkbox and enter the IP address of the slave...

Page 37: ...ppLoxx Pro Controls has been successful this will be displayed at the bottom screen edge If you then log in to a slave control as an administrator you will be able to see the slave status of the wAppL...

Page 38: ...this slave control are programmed and managed The rights and user management is carried out via the master control Now the desired wAppLoxx Pro Cylinder can be programmed in the slave control The info...

Page 39: ...can also be performed in any order and changed at any time We recommend the following approach for the initial commissioning process 1 Create doors create wAppLoxx Cylinder 2 Program the reset card 3...

Page 40: ...Pro Control Complete Instructions All wAppLoxx Pro Cylinders that have been created are displayed in the door overview with their signal strength and battery status This also includes Edit Lock and De...

Page 41: ...one select No to continue counting the openings cycles Making the wrong selection here can mean that the cylinder does not give a battery warning at the right time and that it will no longer be possib...

Page 42: ...er is set to programming or unpairing mode by presenting the system card The system card can be used for any wAppLoxx Pro Cylinder Reset card In order to prevent unauthorised unpairing of the cylinder...

Page 43: ...this function in the selection field Only one wAppLoxx can be defined as a reader for each wAppLoxx Pro Control Programming To program a wAppLoxx in the wAppLoxx Pro Control click on the Program butto...

Page 44: ...ting schedules see Chapter 9 It should however be noted that permanent access cannot be activated for an Intrusion cylinder that is armed This must first be disarmed by an authorised person 8 2 Schedu...

Page 45: ...of schedules To select access times select the appropriate bars using the mouse PC or your finger tablet smartphone One bar represents 15 minutes Example The bar above 6 represents the period from 06...

Page 46: ...holiday schedules to the respective general schedules The holiday access times that have been set in the schedules are applicable on the selected holiday days 8 4 User groups Individual users are gro...

Page 47: ...ere you have the option to select a schedule for the access group Holiday Here you have the option of checking this box to activate the holiday function for this user group 8 5 Users and tags Creating...

Page 48: ...ewing the door protocols This is achieved by clicking on Enable event log Users must log into their own user interface see Chapter 14 to execute these functions Users must enter a user name and passwo...

Page 49: ...d to have been configured see Chapter 13 1 Enable arm disarm Users are authorised to arm and disarm the door systems for the selected access group Arm only Users are only authorised to arm the door sy...

Page 50: ...fallback tags with each wAppLoxx Cylinder If do you not wish to have a fallback function for one or several cylinders these must be declared as exceptions When you select the fallback authorisation al...

Page 51: ...hom the tag is assigned Export To export the user list click on the Export button The file is exported in CSV format Select the UTF 8 format when opening the CSV file to ensure it displays correctly 1...

Page 52: ...oxx Pro Control Complete Instructions In the text import wizard select file origin Unicode UTF 8 and make sure that Delimited is selected Then click Next 4 Select Tab and Comma as delimiters and click...

Page 53: ...53 wAppLoxx Pro Control Complete Instructions Now select the data format General and click on Finish...

Page 54: ...ers e g in the event of a recovery of the wAppLoxx Pro Control system For a successful user import the data and column names must be created as a csv file as shown in the example Restoring the setting...

Page 55: ...ngle permission Access authorisation is granted for the selected door group Remove permission Access authorisation is removed from the selected door group and its subordinate groups Example see above...

Page 56: ...t to enter the local connection data of the desired camera in order to access the camera even externally via the app A connection to the ABUS server is no longer absolutely necessary If you are using...

Page 57: ...57 wAppLoxx Pro Control Complete Instructions 10 Events...

Page 58: ...lay types required by the alarm panel you have connected Open latched Relay closed when armed Closed latched Relay open when armed Open timed Relay closes for one second when armed Closed timed Relay...

Page 59: ...status the wAppLoxx Pro Control is also switched between armed and disarmed accordingly This ensures that the connected alarm panel and the wAppLoxx Pro Control have the same status Input 2 is used by...

Page 60: ...layed If this option is checked then this input is active Connection to the alarm panel There are four options available for connecting the wAppLoxx Pro Control to an alarm panel 1 Alarm system fully...

Page 61: ...and Arm Output options are connected to the alarm panel This makes it possible to arm and disarm the system using the wAppLoxx Pro Control however there is no forced action requested via the alarm pa...

Page 62: ...system is unarmed 4 No alarm panel locking function via wAppLoxx Pro Control Only the Arm Output of the wAppLoxx Pro Control is configured although it is not connected This makes it possible to lock...

Page 63: ...63 wAppLoxx Pro Control Complete Instructions Configuration of the wAppLoxx Pro Control to the Secvest alarm panel interface...

Page 64: ...pLoxx Pro Control Complete Instructions Configuration of the wAppLoxx Pro Control to the Secvest alarm panel interface tamper contact Configuration of the wAppLoxx Control for monitoring cover back ta...

Page 65: ...65 wAppLoxx Pro Control Complete Instructions Configuration of the zone type on the Secvest Configuration of wired zone 301 as key switch duration on the Secvest...

Page 66: ...tructions Configuration of wired zone 302 as a tamper zone on the Secvest Configuration of the wired output 301 relay 01 for the ready signal on the Secvest Configuration of the wired output 302 relay...

Page 67: ...Complete Instructions 10 3 Creating events To create an event select Events in the main menu then click on Create Event An event always comprises an action and a reaction Enter a name for the event a...

Page 68: ...d at a selected door Only the tags that function with the set mode are recorded Tamper Action starts as soon as the tamper contact is interrupted Battery warning Action starts as soon as the selected...

Page 69: ...after an action a relay is to be triggered as a reaction select relay output 2 relay connection 2 see Chapter 3 Type Choose between the various relay types Open timed Relay closes for a set period wh...

Page 70: ...ox to activate monitoring of the cover tamper switch Back tamper Check this box to activate monitoring of the back tamper switch As soon as monitoring is activated the Tamper event type can trigger an...

Page 71: ...te Event should be triggered Status Indicates whether the condition for releasing the cylinder has been met Locking function cylinder locking controlled via external activation The locking function en...

Page 72: ...s the user level please enter the user data User data is created in the administrator user menu Chapter 11 Users We recommend that users change their password after starting up for the first time When...

Page 73: ...e remote control function of the wAppLoxx Pro Cylinder for 30 seconds Pressing it again stops the function immediately After activating the remote opening function the outer knob on the wAppLoxx Cylin...

Page 74: ...col event log To protect sensitive personal data the wAppLoxx Pro Control can be configured so that the event log is only displayed after a second authorised user logs in The four eyes principle can b...

Page 75: ...Access denied Four eyes principle Remote opening Login failed Unknown tag System start Armed System reboot Disarmed Reset to factory default Battery warning External input Supervision loss Tamper Enab...

Page 76: ...may only be used after the user has agreed to the conditions of use according to Article 7 of the GDPR The user hereby agrees to provide the following data to the wAppLoxx online service which is requ...

Page 77: ...f your personal data Please contact us at datenschutz abus de You are required to connect your wAppLoxx product to our online services in order to access the full range of functions In the event of a...

Page 78: ...of with domestic waste At the end of its lifespan dispose of the product according to the applicable legal requirements Please contact your dealer or dispose of the products at the local collection po...

Page 79: ...79 wAppLoxx Pro Control Complete Instructions ABUS Security Center GmbH Co KG Linker Kreuthweg 5 86444 Affing Germany...