Settings
122
Write Community
Enter the “Key” according to the set-
tings of your SNMP software.
Trap Adresse
Enter the IP address of the
SNMP manager
Trap Port
Enter the trap port
(Default: 162)
Note
SNMP is used for monitoring the device status.
For this you need SNMP software not available
from ABUS.
Confirm the settings by clicking
Apply
and leave the
menu with
Back.
More settings
Parameter
Setting
Alarm Host IP
Network address of the PC where the
CMS is installed
Alarm Host Port
Port of your CMS Station
Server Port
Port for data communication (Gen-
eral: 8000)
HTTP Port
Port for web server (General: 80)
Multicast IP
In order to minimize traffic you can
enter a Multicast IP. The IP address
has to match the IP address of the
PC running the CMS software.
RTSP Service
Port
RTSP-port
(Default: 554)
Note
Server port 8000 and HTTP port 80 are the stan-
dard ports for remote clients and remote Internet
browser access.
Note
With Alarm Host IP/Port you configure the address
of your CMS software. The CMS software is noti-
fied when there is an alarm, and performs various
reactions depending on the setting.