– 36 –
METHOD OF FUNCTIONING
Heat warning function:
• Heat warning function is triggered
at 60°C
• Single beep every second
ALARM AND INDICATION SOUNDS
Indication sounds:
When the device is activated a
simple sound is emitted once
(short beep)
Volume:
Cause: Activation sound
Indication sounds:
When the Test/Stop button is pressed
a single sound (long beep) is issued.
Volume:
Cause: Test sound
Alarm sounds:
A two-part signal is issued (short
beep followed by longer beep)
every second.
Volume:
Cause: Smoke alarm
Alarm sounds:
A single tone is issued every second
(short beep).
Volume:
0,5 seconds
1 second