background image

 

English 

1.3.  Operating principle 

The device was developed for use in alarm and home automation systems that use the Z-Wave wireless 
standard. The device has the following functions: 

 

Motion detector

 

It uses Passive Infrared (PIR) technology to detect movement in a defined area by detecting the 
changes in thermal radiation caused by the moving body inside or outside the detection zone. 
With the dual PIR sensor (dual-lens technology), the sensor hides pets up to approx. 38kg, so 
that your pet can move freely without triggering the sensor.  
When the motion detector is triggered, an alarm signal is sent to the Z-Wave controller. The 
indicator LED lights up when motion is detected. 

 

Integrated temperature and humidity sensor 

At periodic intervals, the unit automatically sends the measured temperature and humidity value 
to the Z-Wave controller or on request of the Z-Wave controller.  

 

Tamper protection between the device and wall bracket 

When the housing is opened, the tamper switch is triggered and the device sends a tamper 
alarm to the Z-Wave controller. The tamper contact must remain pressed for three seconds to 
reset the tamper alarm. 

 

1.4.  Performance features 

The device..: 

 

...is a battery-powered motion detector  

 

...is due to its design only suitable for wall mounting 

 

...is Z-Wave Plus compatible & certified 

 

...supports the Z-Wave S2 standard (Security 2) 

 

...has a low-battery warning function 

 

...was developed for indoor installation 

 

1.5.  Use in systems of different manufacturers 

Communication is via the Z-Wave EU frequency (868.4 Mhz). You can integrate the device into any Z-
Wave network with a certified Z-Wave controller, regardless of manufacturer. All non-battery powered 
nodes in the network act as amplifiers to amplify the wireless communication of the network. 

 

1.6.  DSK code 

The DSK code (Device-Specific Key) is the device-specific key of your device and is required for secure 
teach-in (inclusion) via S2 on the Z-Wave controller. The first 5 digits of the DSK code can be found on 
the QR Code sticker on the backside of the bracket of the product. Please enter them in the inclusion 
process when prompted. Alternatively, you can transfer the entire DSK code that you find on the 
enclosed DSK card to the Z-Wave controller via QR Code Scan.  Please keep the DSK card in a safe 
place!

 

 

Hint:  

We recommend the secure S2 inclusion (must be supported by the Z-Wave controller) When prompted, 
please enter the 5 digits of the DSK code (bottom of the device) or the complete DSK code (QR code).

 

 

 

 

Summary of Contents for PLBW10000

Page 1: ...PLBW10000 Nexello Dual Motion Detector Important information and FAQs about this product and other products can be found on the website www abus com Manual version 1 2 Firmware version 1 01...

Page 2: ...eg 5 86444 Affing Germany E mail support abus sc com Phone 49 8207 959 90 0 Opening hours hotline Mon Thu 08 17 h Fri 08 14 h All contained company names and product names are trademarks of their resp...

Page 3: ...the technical data of the individual devices Ensure that there is always adequate ventilation no direct heat sources are applied to the device no direct sunlight or strong artificial light is applied...

Page 4: ...st be cleaned Dust deposits in the air slots can be sucked off or blown out If necessary the dust can be removed with a brush The surface can be cleaned with a cloth slightly moistened with soapy wate...

Page 5: ...w 8 2 1 Inclusion teach in device 8 2 2 Planning mounting and installation 9 2 3 Exclusion teach out device 11 2 4 Reset factory settings 12 2 5 Waking up the device Wake up 12 2 6 Behavior PIR sensor...

Page 6: ...ower Fresnel Lens For motion detection D Tamper contact Triggers Tamper alarm E Link Button Manual triggering of the wake up command inclusion exclusion and reset F Battery compartment Observe polarit...

Page 7: ...alarm 1 4 Performance features The device is a battery powered motion detector is due to its design only suitable for wall mounting is Z Wave Plus compatible certified supports the Z Wave S2 standard...

Page 8: ...device supports automatic inclusion i e it automatically goes into inclusion mode when it is powered and not yet connected to a Z Wave controller The LED starts flashing Alternative manual inclusion...

Page 9: ...ge is sent If there is no movement the reset message is sent Use the test mode to select the optimal installation location Select installation location The detector is only suitable for indoor install...

Page 10: ...is still triggered by the pet Do not mount the detector too high otherwise it will not be triggered by humans Use the bracket as a template to mark the position of two drill holes on the wall There ar...

Page 11: ...e controller manual for more details Press the button Remove Exclusion in your Z Wave app and follow the instructions to set the Z Wave controller to Exclusion mode Press the Link button 3 times quick...

Page 12: ...settings Hint This procedure should only be used if the primary network controller is not capable of acting If the device is set to factory default the status is set to not included and the associatio...

Page 13: ...hem again PIR waiting time As soon as motion is detected the device s LED lights up and it sends a motion alarm to the Z Wave controller The device now waits for a preset time waiting time until it re...

Page 14: ...mmand class Group 1 1 Lifeline General Notification report Battery report Device Reset Locally Notification Sensor Multilevel Report Group 2 4 PIR control Notification Basic set Group 1 Association Z...

Page 15: ...x01 0x08 Tamper alarm 0x07 0x03 0x00 Tamper alarm reset no Event 0x07 0x00 0x01 0x03 Battery report Value Description 0x14 0x64 20 100 Battery charge level in percentage 0xFF 256 Low battery Sensor Mu...

Page 16: ...motion alarm to the next triggering Adjustable from 10 3600 in seconds Hexadecimal 0x10 0xE10 3 2 Reset waiting time after motion alarm Association Group 2 180 Waiting time after a movement alarm unti...

Page 17: ...MWARE_UPDATE_MD Version 4 MANUFACTURER_SPECIFIC Version 2 NOTIFICATION Version 8 POWERLEVEL Version 1 SECURITY Version 1 SECURITY_2 Version 1 SENSOR_MULTILEVEL Version 5 SUPERVISION Version 1 TRANSPOR...

Page 18: ...DC Type of battery 1x CR123 GP Battery life 2 years based on per day 20x trigger 48 hygrometer multisensor reports 4 wakeup Tamper protection yes Firmware updateable Yes OTA Z Wave Manufacturer ID 0x0...