10.2 Learning in
The detector transmits its identity to the receiver either wirelessly or using infrared via the activity LED.
Switch the wireless alarm control panel or the receiver to learning mode. See the relevant receiver
instructions for more details.
Wireless option:
Press and hold the test button for 3 seconds. When the alarm sounds, the detector is sending its identity
by wireless.
Infrared option:
Hold the detector so that the activity LED is positioned over the receiver's IR learning sensor and is
pointing in its direction. Position the activity LED as closely as possible to the IR learning sensor. Press
and hold the test button for 3 seconds. When the alarm sounds, the detector is transmitting its identity in
the IR section of the light to the receiver's learning sensor.
10.3 LED display
If the detector is working properly, the activity LED flashes once every 60 seconds. The detector is not
signalling an alarm.
This flashing can be deactivated using a DIP switch. The DIP switch is located in the battery
compartment, see Fig 4.
a) The activity LED flashes once every 60 seconds during normal operation
DIP 1 = ON, DIP 2 = ON
b) The activity LED will not flash during normal operation
DIP 1 = ON, DIP 2 = OFF