background image

NX Series Product User Manual

31

Center line of screen (composed of big cabinet, 960*540*43.5mm)

lower left Wall connector (the lowest hole);

When the screen is a cabinet with five or more rows and the number of

rows is odd:

When the cabinet is greater than or equal to five rows and the number of rows

is an odd number, use one double vertical bar every three cabinets, and use

one if the mantissa is less than three;

X1 calculation method: divide the screen length of the large cabinet by 2, then

subtract 480 (unit: mm);

Y3 calculation method: the distance from the screen to the ground plus 1020

(unit: mm);

Note: The calculation units are all millimeters (mm), and the above is the

calculation method for big cabinets (the calculation methods for big cabinets

and small cabinets are different):

Y is the distance from the first wall connector on the lower left (the lowest hole)

to the ground;

X is the distance from the center line of the screen of the big cabinet to the

lower left Wall connector (the lowest hole);

Calculation method of positioning of small cabinet wall connectors;

Summary of Contents for NX Series

Page 1: ...NX Series Product User Manual NX1 5 NX1 8 NX2 5 NX3 7 Shenzhen Absen Optoelectronic Co Ltd...

Page 2: ...tion 19 3 1 stacking installation 20 3 2 Hanging installation 24 3 3 Wall mounting 27 3 4 Trim pieces installation 38 4 Product Wiring 42 4 1 Preparation before connection 42 4 2 Power cable connectio...

Page 3: ...se disconnect the device s power supply or provide other suitable lightning protection If the equipment is not in use for a long time please unplug the power cable When performing any installation or...

Page 4: ...ents and steel frames are securely installed When installing repairing or moving the product ensure the working area is free of obstacles and ensure the working platform is securely and stably fixed I...

Page 5: ...e interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a...

Page 6: ...nt 1 Product Introduction As a symbol of infinite possibilities letter X becomes an exterior design element of the cabinet and the Xs will form a honeycomb an Absen brand element The unique design con...

Page 7: ...NX Series Product User Manual 6 45 degree cut angle on both sides of the small cabinet Default 45 angle on both sides 240mm 43 5mm 960mm 540mm 43 5mm X1 X4...

Page 8: ...etc Commercial real estate shopping mall atrium shopping mall entrance shopping mall aisle etc Enterprise enterprise lobby enterprise exhibition hall enterprise conference room monitoring center etc T...

Page 9: ...he cover Product comes standard with ultra thin and textured trim pieces Metal spraying ultra thin standard trim pieces solution for enhanced look and esthetic feeling The receiving card is connected...

Page 10: ...nd double backup version are not included Passed the T V Rheinland low blue light certification filters out harmful blue light and protects eyes The cabinet supports signal loop backup The attenuation...

Page 11: ...ale bit 16 Contrast Ratio 4000 1 4000 1 4500 1 5200 1 Color Temperature K 6500 Viewing Angle H V 150 150 160 160 160 160 160 160 Driving Type 1 45 1 36 1 27 1 18 AC Operating Voltage V 100 240 Power C...

Page 12: ...500 1 5200 1 Color Temperature K 6500 Viewing Angle H V 150 150 160 160 160 160 160 160 Driving Type 1 45 1 36 1 27 1 18 AC Operating Voltage V 100 240 Power Consumption Max Avg W m 480 160 420 140 45...

Page 13: ...ontrast Ratio 6000 1 7600 1 7400 1 Color Temperature K 6500 Viewing Angle H V 160 160 160 130 160 160 Driving Type 1 36 1 27 1 18 AC Operating Voltage V 100 240 Power Consumption Max Avg W m 606 202 5...

Page 14: ...Color Temperature K 6500 Viewing Angle H V 160 160 160 130 160 160 Driving Type 1 36 1 27 1 18 AC Operating Voltage V 100 240 Power Consumption Max Avg W m 606 202 534 178 609 203 Application Paramete...

Page 15: ...NX Series Product User Manual 14 2 Introduction of Product Components 2 1 Product size introduction 2 1 1 Cabinet size drawing 960mm 540mm...

Page 16: ...NX Series Product User Manual 15 Default 45 angle on both sides 540mm 240mm...

Page 17: ...NX Series Product User Manual 16 2 1 2 Module size drawing 240mm 270mm...

Page 18: ...ntroduction of cabinet components 2 2 1 Cabinet size 960 540mm Carrying handle Installation handles Left and right wiring holes v Structural design of protective lamp Rotary clamshell design Z axis ad...

Page 19: ...of the screen One cabinet is equipped with two connecting blocks Mounting screw cylindrical inner hexagon full thread machine screw M6 60mm v v v Default 45 angle on both sides Small connecting block...

Page 20: ...d stacking installation Installation tool list Tool type function picture knife Open the cabinet Front maintenance tool Install maintain the LED module Socket hexagon wrench Install the screws between...

Page 21: ...f the screen Right angle installation When the small cabinet is assembled at a right angle use the middle of the screen When the small cabinet is assembled at right angles use the upper and lower trim...

Page 22: ...e After M6 80mm screws pass through the cabinet the connecting plate on the back of the cabinet the square tube with a width of 40mm and the connecting plate on the back of the square tube use the M6...

Page 23: ...inet open the back cover of the cabinet Note During the installation process ensure the flatness of the cabinet structure splicing 3 Install the second layer of the cabinet first use M8 40mm bolts to...

Page 24: ...User Manual 23 4 Follow the above steps to complete the installation of all cabinet structures 5 After installing the power cable and network cable of the cabinet and checking that they are correct i...

Page 25: ...40X540mm single hanging beam 480mm Small cabinet 240X540mm double hanging beam M8 40mm The hexagon socket head machine screw is used to connect the hanging beam and the cabinet 3 2 2 Installation step...

Page 26: ...ix after confirming that they are flat Note Use connecting blocks to install between large and small cabinets Mounting screw cylindrical inner hexagon full thread machine screw M6 60mm 3 Install the c...

Page 27: ...es Product User Manual 26 5 Install the power cable and signal cable according to the power supply and signal routing design scheme and then install the LED module after power on inspection and confir...

Page 28: ...Big cabinet 960 540mm horizontal bar connector connector Connect the two vertical bar Small cabinet 240 540mm horizontal bar horizontal bar Small cabinet 240 540mm horizontal bar connector connector C...

Page 29: ...calculation method divide the screen length of the big cabinet by 2 then subtract 480 unit mm Y1 calculation method the distance from the screen to the ground minus 24 unit mm Note The calculation uni...

Page 30: ...thod the distance from the screen to the ground plus 480 unit mm Note The calculation units are all millimeters mm and the above is the calculation method for big cabinets the calculation methods for...

Page 31: ...connector the lowest hole When the screen is a cabinet with four or more rows and the number of rows is an even number When the cabinet is greater than or equal to four rows and the number of rows is...

Page 32: ...od divide the screen length of the large cabinet by 2 then subtract 480 unit mm Y3 calculation method the distance from the screen to the ground plus 1020 unit mm Note The calculation units are all mi...

Page 33: ...inet install the small cabinet No matter whether the small cabinet is installed on the left or right install the large cabinet first and then install the small cabinet Note The small cabinet is instal...

Page 34: ...ed screws pass through the wall connector and are embedded in the bar and lock the wall connector and the horizontal bar with nuts The connection between the horizontal bars is locked up and down by t...

Page 35: ...ble for 240 540 cabinet structure double frame kit Suitable for 240 1080 cabinet structure Big cabinet 960 540mm frame kit single frame kit Suitable for 960 540 cabinet structure Screws M6 external he...

Page 36: ...frames install the cabinet frame on the frame kit install it layer by layer from bottom to top and fasten the connecting screws between the cabinets to fix the cabinet Note Arrange the main power cab...

Page 37: ...NX Series Product User Manual 36 4 After installing all the cabinets connect the signal cable and power cable...

Page 38: ...t of the big cabinet the upper modules are XX 1 XX 2 XX 3 XX 4 from left to right and the lower modules are XX 5 XX 6 XX 7 XX 8 Note XX represents the cabinet number each cabinet has a different numbe...

Page 39: ...gle trim pieces 540mm Left and right standard double trim pieces 1080mm Upper and lower single length trim pieces with chamfer small cabinet use 240mm trim pieces thickness Top left bottom right fixed...

Page 40: ...NX Series Product User Manual 39 the upper side is shorter 5 The long edge covers the short edge The oblique side of the small cabinet is supported and fixed by the connecting block...

Page 41: ...NX Series Product User Manual 40 3 4 3 Trim pieces Scheme diagram a The trim pieces of the screen composed of big cabinets...

Page 42: ...NX Series Product User Manual 41 b The trim pieces of the screen composed of small cabinets...

Page 43: ...ion cabinet manufacturer The input voltage of the cabinet is 100 240V AC and a 3X1 5mm power cable is used from the distribution cabinet to the cabinet Please confirm the input voltage different volta...

Page 44: ...the pixel range cannot exceed 655360 points as shown below The following takes a 3x3 NX1 8 cabinet as an example to introduce the connection method of the power cable The number of pixels of a single...

Page 45: ...t circuit at the AC input L N PE and DC output VCC GND of the power supply If a short circuit is found please check the circuit carefully After ensuring the cable is normal switch on the power to elec...

Page 46: ...t Maintenance 5 1 Preparation Tools Module front service tool Installation and removal LED module multimeter Measure power cables and distribution cabinetes Allen key Removing installing the screws of...

Page 47: ...4 Lightly install the spare module on the screen according to the upward direction Precautions The front maintenance tool should be placed in the middle of a single module and should not cross over t...

Page 48: ...ard 3 Then use the PH2 Phillips screwdriver to remove the screws on the fixed hub board then it can be removed and replaced 5 3 3 PSU maintenance 1 First use the pre maintenance tool to remove the mod...

Page 49: ...e once reversed the product will be burnt out and even cause serious fire 2 Power supply voltage of LED display 220V 10 Frequency 50HZ 5 3 Safe and reliable earth contact reliable isolation between th...

Page 50: ...conditions of the display screen and the control part avoid insect bites and put anti rodent drugs if necessary 3 The LED display should not be turned off for a long time In a high humidity environme...

Page 51: ...is loose 3 Check whether the main data cable is inserted tightly 4 Check whether the sending card is powered on and whether the running indicator is flashing 5 Replace the sending card 6 Connecting t...

Page 52: ...k whether the sending card data port is malfunctioning 6 Re add the multi function card 7 Replace the multi function card 8 Replace the sending card 8 No full screen display 1 Check whether the settin...

Reviews: