background image

Absco Industries

Assembly Instruction Manual

ABSCO UTILITY SHED

MODEL: 3060UTK

3.00mW x 5.96mD x 2.10mH

Model: 3060UTK

2/05/2019

1.2

41  

 

 

FRONT FRAME ASSEMBLY SUPPORT PHOTOS

STEP 5.
Join K0285 to C1785 & N1820.

Summary of Contents for 3060UTK

Page 1: ...g please contact us admin absco com au or 1800 029 701 ABSCO INDUSTRIES ASSEMBLY INSTRUCTION MANUAL SHED MODEL 23151GK 21 11 2017 CONCRETE SLAB 2360mm 1620mm FRONT 2 26m SIDE 1 52m HEIGHT 1 95m We thank you for choosing an Australian made shed For further assistance please visit our detailed instructional video library at Http www abscosheds com au watch videos At ABSCO Industries we are always lo...

Page 2: ...ected your site you will need to lodge a site plan to your local council SITE PREPARATION The site for the shed must be level An uneven surface may result in misalignment of parts The shed shall be erected on top of a reinforced concrete slab and anchored down appropriately illustrated on FINAL CONSTRUCTION page If using a rebated slab ensure that all frame uprights are trimmed 25mm TOOLS REQUIRED...

Page 3: ... 1 16 2 STEEL SHEET 1915mm X 773mm 36L STEEL SHEET 2045mm X 773mm 38L STEEL SHEET 1546mm X 773mm 45A STEEL SHEET 1725mm X 773mm 25A 1 1 1 2 15A PEAK BRACE STEEL SHEET 1725mm X 711mm 37A STEEL SHEET 1725mm X 773mm B 1 FITTINGS ACCESSORIES PACKET SEE PG 4 97AL RIDGE BEAM L 1521mm STEEL SHEET 1785mm X 731mm 33A 1 STEEL SHEET 1785mm X 731mm 32A 2 STEEL SHEET 1785mm X 329mm 39B 1 1 GABLE L H L 1475mm 1...

Page 4: ...T 115mm LONG FAST006 2 PADBOLT HASP FAST007 1 3mm DRILL BIT DRILL 1 SCREW PACK 12 PACK12P 1 PHILLIPS HEAD DRIVER BIT S2 PH2 FAST038 1 8G x 3 8 SELF TAPPING SCREWS x 220 PACK220 PACK12P SCREW PACK 12 12 SBS43E POP RIVET FAST009 12 3 16 x 1 2 COUNTERSUNK SCREW NUT FAST004 FAST005 8 3 16 x 1 2 PAN HEAD SCREW FAST002 8 3 16 NYLOCK NUT FAST003 PSTKSGL SINGLE DOOR FITTINGS PACK 1 PADBOLT 115mm LONG FAST...

Page 5: ...K CONTENTS 80mm X 40mm CHANNEL SECTIONS COMPONENT DESCRIPTION PART No CHECK CHECK QTY QTY PORTAL FRAME ACCESSORIES CHECK C1482 COMPONENT DESCRIPTION PART No C1704 CHANNEL L 1482mm 40 80 CHANNEL L 1704mm 40 80 KNEE PLATE APEX PLATE 10mm DYNABOLTS 16mm TEK SCREWS STEEL SHEET 1915mm X 773mm 36R STEEL SHEET 2045mm X 773mm 38R MULTI PURPOSE BRACKET 45mm TEK SCREWS COMPONENT DESCRIPTION PART No CHECK CO...

Page 6: ... No CHECK COMPONENT DESCRIPTION PART No CHECK QTY QTY 1 1 1 3 3 5 81BL CHANNEL L 1496 5mm 81AL CHANNEL L 1496 5mm 56BL CHANNEL L 1496 5mm 77CL CHANNEL L 1496 5mm 56AL CHANNEL L 1496 5mm 55BL CHANNEL L 1496 5mm 60AL 4 CHANNEL L 1496 5mm 1 1 1 3 3 5 81BR CHANNEL L 1496 5mm 81AR CHANNEL L 1496 5mm 56BR CHANNEL L 1496 5mm 77CR CHANNEL L 1496 5mm 56AR CHANNEL L 1496 5mm 55BR CHANNEL L 1496 5mm 60AR 4 C...

Page 7: ...546mm MAIN PACK PACK 2 OF 3 CHANNEL SET CONT COMPONENT DESCRIPTION PART No CHECK COMPONENT DESCRIPTION PART No CHECK QTY QTY 90B JAMB L 788mm 91A JAMB L 1120mm 1 2 3 89A JAMB L 1785mm 1 1 2 4 2 58A CHANNEL WITH HINGES L 1725mm 3 CHANNEL L 1518mm 84L 79B CHANNEL L 788mm 89B JAMB L 1785mm 1 CHANNEL L 1518mm 84R 1 58B CHANNEL L 1725mm 63A CHANNEL L 1155mm 58C CHANNEL L 773mm 2 81M CHANNEL L 329mm 1 9...

Page 8: ...QTY QTY 2 2 2 8 2 2 C2300 N1820 C1785 M1484 K0285 C0240 C0100 CHANNEL L 2300mm 40 80 CHANNEL L 1820mm 40 80 CHANNEL L 1785mm 40 80 CHANNEL L 1484mm 40 80 CHANNEL L 100mm 40 80 CHANNEL L 240mm 40 80 CHANNEL L 285mm 40 80 10 1 COMPONENT DESCRIPTION PART No CHECK COMPONENT DESCRIPTION PART No CHECK QTY QTY 1 4 99A HAT 2290mm 99B HAT 1350mm MULTI PURPOSE BRACKET SMALL TRIANGULAR PLATE 150 SELF DRILLIN...

Page 9: ... order to split the sheet lay it on the ground and lift and fold one end until the perforations have cleanly snapped Discard the middle piece as scrap when convenient Fold the scrap piece in half two or three times and throw in garbage Check sheet for perforations Fold first side of sheet until free Fold middle section of sheet until free Discard middle piece SCRAP SCRAP SCRAP SCR AP SCRAP SCRAP S...

Page 10: ...he channel along the sheets until each end is neatly flush If you need to remove channels from the panels slide it off from the side Channel locks the shed panel into position without the need for screws FASTENING SYMBOLS Secure channel to sheeting by SNAPTiTE fastening method Join components together with one screw at this location only as some channels have extra holes that are not required for ...

Page 11: ...e end of the channel where the JOIN text is marked Push down one side of the CSJ until you hear a click Step 3 Join the second channel to the CSJ by positioning the JOIN of the channel at the centre of the CSJ on an angle Push the CSJ into the channel until you hear a click Finished Channel The joined channels should now look like the picture with the CSJ positioned equally inside of the joined ch...

Page 12: ...em You will need to redrill holes where CSJ joining channel covers them Join together 36 x channel sections using 18 x channel joiners Part CSJ 1 X 77CR 2993mm 117 8 5 x 81A 1 x 77C 3 x 55B 1 x 56A 1 x 56B 3 x 81B 81BR 81BL 56BL 56BR 56AR 56AL 55BL 55BR 77CR 77CL 81AL 81AR 5 X 81AR 5 X 81AL 1 X 77CL 3 X 55BR 3 X 55BL 1 X 56AR 1 X 56AL 1 X 56BR 1 X 56BL 3 X 81BR 3 X 81BL 4 X 60AR 4 x 60A 60AR 60AL ...

Page 13: ...a 50mm overlap of the ridge caps when the beams are in position Step 2 Use the ZARSP to connect at the centre of the two ridge beams Be sure it is pushed in fully Step 3 Turn over the ridge beam Measure 250mm from the middle along the centre of one ridge beam mark spacings of 50mm Fasten with a Tek screw at each marking Repeat to the other side of the ridge beam assembly TIP Predrilling each hole ...

Page 14: ...bly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 14 PRE ASSEMBLY OF SPLICED RIDGE BEAM 2x 97AL 2x 97AR 2x 97A 2993mm Overall length ZARSP 225mm 16mm 97AL 97AR 16mm ...

Page 15: ... this will allow the sections to butt up neatly to each other Cut away these two only Self drilling Tek screw 98A ZARSP Tek screw driver bit Push 98A Finished Joined Ridge Beams Insert the ZARSP at an equal distance into each ridge beam Confirm that the beam is straight with a string line before fastening with self drilling screws The ZARSP is a very tight fit tap into place with a hammer ZARSP JO...

Page 16: ...HED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 16 OVERVIEW OF ROOF COMPONENTS OVERVIEW OF ROOF COMPONENTS 87A 87A 81A 60A 60A 97A 14A 45A 45A 45A 45A 45A 45A 45A 45A 81A 98A 60A 60A 97A 87A 87A 14A 45A 45A 45A 45A 45A 45A 45A 45A 81A 81A ...

Page 17: ...RVIEW OF WALL COMPONENTS OVERVIEW OF WALL COMPONENTS DOOR SHEET 1725mm SINGLE 84R 84L 56B 81B 81M 63A 63A 58B 63A 77C FF 58A 81M 89C 89A 99B 81B 79B 89B 89A 90B 91A 15A 22A 12A 58A 58A 58C 89A B 58C 93L 99A 55B BWR BWR BWL BWL 30A 31A 31A 31A 31A 30A 32A 33A 31A 31A 30A 39B 39B 37A 37A 25A 25A 1 6 L 81A 1 6 R 58B 93R 55B 31A 31A 56A 31A ...

Page 18: ... 2 18 ROOF PANEL ASSEMBLY Two panels will have part 87A fitted to this end only Two panels will have part 87A fitted to this end only Fit 81A to edge of sheet with pre punched holes 4 required When completed there will be four sections with 87A lip at one end only SNAPT TE i SNAPT TE i 60A 87A 81A 87A 45A 45A 45A 45A D D D D D D ...

Page 19: ...Model 3060UTK 2 05 2019 1 2 19 SIDE PANEL ASSEMBLY 3 required One panel requries Sheet 30A this end 30A is a corner sheet and must be orientated towards the shed corners when panels finally joined Two panels require Sheet 30A this end SNAPT TE i SNAPT TE i 54B 81D 30A 31A 31A 31A 30A 31A 31A 31A 55B 81B ...

Page 20: ... ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 20 SIDE PANEL ASSEMBLY SINGLE DOOR PANEL 1 required 89B 89A 32A 33A 31A 56A 79B 56B 90B SNAPT TE i SNAPT TE i SNAPT TE i SNAPT TE i 90B 56A 89A 56A 79B 56B 89B ...

Page 21: ...tion of this instruction set for further details and ensure that the assembled panels are not joined together with pre punched holes incorrectly positioned The overall length of each panel is the same as the ridge beam Trim the channels by 16 5mm to allow the sheets to be overlapped Overlap the panels and fasten as shown 16 5 16 5 It is not critical that the overall dimension is exact but try and ...

Page 22: ...D x 2 10mH Model 3060UTK 2 05 2019 1 2 22 DOOR PANEL ASSEMBLY Vertical door channels are installed in the opposite orientation compared to the horizontal door channels Short flange of channel Long flange of channel SINGLE DOOR 58C 58C SNAP T TE i SNAP T TE i 12A B B 58B 58A D D D D 1 required ...

Page 23: ...PANEL NOTE Nuts and bolts are also supplied and may be used instead of rivets Use a 4mm drill bit to enlarge these holes in the jamb NOTE The holes to fasten the padbolt hasp are not pre punched to allow for proper alignment Position the hasp centrally over the padbolt shaft and drill 3mm holes and secure with screws 91A 91A DOOR PANEL ASSEMBLY B ...

Page 24: ...HED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 24 END PANEL ASSEMBLY 1 required 84R 84L 15A 15A 81A TRIM THE TIP OF EACH SHEET OR BEND OUT OF THE WAY TO ALLOW CHANNELS TO FIT HARD UP TO THE EDGE OF THE SHEET 36L 36R 38L 38R INSIDE OF SHED ...

Page 25: ...e horizontal door channels Note These sheets have not been pre punched Short flange of channel Long flange of channel Locate the narrow pan at this end H37 H26 Pre drill door sheets with a 3mm drill bit using the pre punched components shown as templates 63A HC1 12A 63A SNAPT TE i SNAPT TE i Fit one door with a channel HC2 Fit the other with a jamb HJ3 DOOR PANEL ASSEMBLY DOUBLE DOOR D D D D 25A 5...

Page 26: ... cut an amount off the bottom of the frame legs equal to the depth of the rebate TIP An easy way to make sure that the angle at the top of the portal frame is correct is to use the gable wall panel as a template to lay the sections out As the portal frame fits inside the walls the width of the frame will be 40mm less than the gable wall panel NOTE Refer to the section CENTRE PORTAL ASSEMBLY for ph...

Page 27: ...0mH Model 3060UTK 2 05 2019 1 2 27 CENTRE PORTAL FRAME DETAILS STEP 1 Portal to panel connection see section PANEL CONSTRUCTION for further infomation Secure ridge plates to apex plates M10 Dynabolt Portal Self drilling tek screw Wall Roof panel STEP 2 STEP 3 STEP 4 x 19 x 30 x 8 x 8 x 6 2 x 0 8 18 4 ...

Page 28: ...anual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 28 CENTRE PORTAL ASSEMBLY SUPPORT PHOTOS STEP 1 Draw pattern on the concrete in accordance with the dimensions detailed in the assembly instructions ...

Page 29: ...ies Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 29 CENTRE PORTAL ASSEMBLY SUPPORT PHOTOS STEP 2 Understand where components are to be positioned ...

Page 30: ...ndustries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 30 CENTRE PORTAL ASSEMBLY SUPPORT PHOTOS STEP 3 Join rafter to column with knee plate ...

Page 31: ...dustries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 31 CENTRE PORTAL ASSEMBLY SUPPORT PHOTOS STEP 4 Join both rafters using the apex plate ...

Page 32: ...Absco Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 32 CENTRE PORTAL ASSEMBLY SUPPORT PHOTOS STEP 5 Secure ridge plate RBP ...

Page 33: ...co Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 33 CENTRE PORTAL ASSEMBLY SUPPORT PHOTOS STEP 6 Secure multi purpose brackets ...

Page 34: ...ustries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 34 CENTRE PORTAL ASSEMBLY SUPPORT PHOTOS STEP 7 Turn frame over and repeat steps 4 and 5 ...

Page 35: ...O FORM BOXED SECTIONS JOIN PART NUMBERS C2300 C0240 FIT THE CHANNELS WHICH FORM THE BOXED SECTIONS TOGETHER WITH THE SMALLER EDGE NEATLY INSIDE THE LARGER EDGE FASTEN WITH SCREWS AT 300mm SPACINGS WHERE POSSIBLE NOTE THESE FRAMES WILL NEED TO BE TRIMMED 25mm TO FIT REBATE REFER TO THE FOLLOWING PAGE FOR FURTHER DETAILS TRIANGULAR PLATE MULTI PURPOSE BRACKETS N1820 C1785 C0100 K0285 M1484 C0240 RID...

Page 36: ... THE EXTERIOR SIDE OF THE FRAME SECURE THE RIDGE PLATE TO THE INTERIOR SIDE OF THE FRAME 40mm ALL SECTIONS LAYOUT ALL SECTIONS AS SHOWN IN THE SAME MANNER AS THE PORTAL FRAME NOTE IF YOU HAVE AN EDGE REBATE IN YOUR CONCRETE SLAB YOU WILL HAVE TO CUT AN AMOUNT OFF THE BOTTOM OF THE FRAME LEGS EQUAL TO THE DEPTH OF THE REBATE USE 16mm SELF DRILLING SCREWS JOIN ALL COMPONENTS TOGETHER WITH THREE SCRE...

Page 37: ...Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 37 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 1 Draw pattern on the concrete in accordance with the dimensions detailed in the assembly instructions ...

Page 38: ...ries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 38 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 2 Understand where components are to be positioned ...

Page 39: ...stries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 39 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 3 Join C0100 to the bottom of the columns C1785 ...

Page 40: ...o Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 40 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 4 Join rafter M1484 to column C1785 ...

Page 41: ...Absco Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 41 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 5 Join K0285 to C1785 N1820 ...

Page 42: ...Absco Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 42 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 6 Fit mulitpurpose brackets ...

Page 43: ...o Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 43 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 7 Assemble the C0240 C2300 sections ...

Page 44: ...bsco Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 44 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 8 Join all sections together ...

Page 45: ...ndustries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 45 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 9 Turn over frame and repeat steps 4 to 8 ...

Page 46: ...sco Industries Assembly Instruction Manual ABSCO UTILITY SHED MODEL 3060UTK 3 00mW x 5 96mD x 2 10mH Model 3060UTK 2 05 2019 1 2 46 FRONT FRAME ASSEMBLY SUPPORT PHOTOS STEP 10 Fully assembled front frame ...

Page 47: ...ULD FINISH FLUSH WITH THE EDGE OF THE FRONT FRAME THUS FORMING A WEATHERPROOF REBATE FOR THE DOORS FIG A NOTE THE OUTER EDGE OF THE FRONT PANEL SHOULD PROTRUDE 20mm PAST THE OUTER EDGE OF THE FRONT FRAME FOR CORNER LAPPING OF SIDE WALL PANELS FIG B LEFT HAND FRONT FRAME RIGHT HAND FRONT FRAME FIG A FIG A FIG B FIG B PRE PUNCHED HOLES TO OUTSIDE EDGE SNAPT TE i SNAPT TE i SNAPT TE i SNAPT TE i 77C ...

Page 48: ...rames into postion mark and drill holes in slab using 10mm masonry drill bit Secure frames to slab with M10 dynabolts Recommended slab dimensions 6060mm x 3100mm External wall dimensions 5960mm x 3000mm Internal wall dimensions 5920mm x 2960mm Centre of portal frames Concrete slab 6060mm x 3100mm Multi purpose brackets 80mm long FIG 8A 6060 3100 SLAB EDGE 6 0 6 0 m m Centre frame upright Front fra...

Page 49: ...eting The base channels are not Side wall channels fit into the notched rear wall channels Use 45mm self drilling screws to secure walls to centre frame Use 16mm self drilling screws to secure walls to front frame Pre punched channel to match ridge beam holes Pre punched holes in roof panel to this side for connection to front and rear walls With a concrete slab drill a 10mm hole instead of using ...

Page 50: ... A below STEP 2 Move the other roof panel into position and secure peak brace to ridge beam and roof panel with one screw at each end see B below STEP 3 Secure both roof panels to the walls with one screw in each corner first followed by two screws adjacent to the portal frame as shown STEP 4 Secure roof panels to the top chords of the portal frame using 45mm self drilling tek screws WARNING Do no...

Page 51: ... Denotes hot dip galvanised finish Wall Sheet Slab 15 15 STEP 1 Secure the roof panels to the wall panels as shown STEP 2 Secure the roof panels to the internal frames with self drilling tek screws STEP 3 Secure the portal frames to the ridge beam as detailed on the previous page STEP 4 Bend the top and bottom flanges as shown then hook the bottom flanges under the top channel and screw top to the...

Page 52: ... the side door was fitted Fit door braces 99B to each door as shown by fastening at each end then drilling remaining holes from the inside face of each door Secure with screws from the outside face of each door FASTEN TO SLAB DRILL 12mm HOLE CENTRALLY TO PICK UP PADBOLT USE THE 75mm JAMB SECTIONS 93B AS PADBOLT SUPPORTS DRILL AND SECURE THESE SECTIONS TO THE TOP AND BOTTOM OF THE DOOR THEN FIT PAD...

Page 53: ... installation contractor Scaling of drawings shall not be undertaken 7 G Prior to commencing works on site the contractor shall verify the position of all services in the area to ensure that the construction does not interfere with any of those services 8 G During installation on site the shed structures shall be maintained in a stable condition with no part becoming overstressed or permanently de...

Page 54: ...x45x3EA x 34mm long and 47x47x1 9EA x 80 long shall be minimum Grade 450 4 S All portal frame knee and apex plates shall be minimum Grade 450 5 S All roof and wall sheeting shall be minimum base metal thickness of 0 3mm 6 S All portal frame members shall be minimum base metal thickness of 0 75mm 7 S All snaptite channels and jambs shall be minimum base metal thickness of 0 42mm 8 S All top hats sh...

Page 55: ...lified structural engineer The design shall consider all relevant provisions of AS3600 and AS2870 3 F Between adjacent footings or excavations the contractor installing the slab foundation shall not exceed a rise of 1 in a run of 2 in line of slope 4 F Unless approved in writing by the slab foundation engineer the limits of excavations near existing footings shall be in accordance with that indica...

Page 56: ...lbarrows garden tools etc Storage items that might be adversely affected by any of the above conditions may require additional protection such as being sealed or covered by plastic sheets and or stacked above the concrete floor on timber slats Waterproof sealants may be used to offer further protection where required around joins and screw fixings as can rubber door seals and other products which ...

Page 57: ...ss of claiming warranty To make a claim under the warranty within the warranty period you will need to contact the manufacturer directly by phone or email Contact Number 1800 029 701 Contact Email admin absco com au You will be required to produce proof of purchase this is at discretion of the manufacturer at the time of the claim The manufacturer bears the cost of replacing the products or spare ...

Page 58: ... prone to damage if they come into contact with moisture We recommend you use a waterproof sealant to fill any gaps or joins in order to minimise the risk of water entering 3 Major Defects If the manufacturer is satisfied that the defect is a major defect the purchase price may be refunded in lieu of providing a replacement product or repairing the product This warranty is provided in addition to ...

Reviews: