background image

 

Installation and Operating Instructions

ABS lifting station Nirolift & Sanisett 

ABS reserves the right to alter specifications due to technical developments

Contents

General ...................................................................................................................................................3

1.1 

Application areas .....................................................................................................................................3

1.2 

Installation example and dimensions.

 ..................................................................................................... 3

1.3 

Commentary on the legal regulations covering the use of lifting stations for the pumping of faecal free 

effluent.

 ...................................................................................................................................................5

1.4 

Description ..............................................................................................................................................5

 

Safety .....................................................................................................................................................5

Transport ................................................................................................................................................5

Set-up and Installation ..........................................................................................................................6

4.1 

Installation of the collection tank ............................................................................................................. 6

4.2 

Installation of the submersible pump ....................................................................................................... 6

4.3 

Opening of the collection tank inlet ports ................................................................................................ 7

4.4 

Discharge line .........................................................................................................................................7

4.5 

Mounting of the upper fitting

 ....................................................................................................................7

4.6 

Location of power supply cable and float switch

 ..................................................................................... 7

4.7 

Level control ............................................................................................................................................8

4.8 

Installation of the control unit ..................................................................................................................8

Commissioning .....................................................................................................................................8

Maintenance ..........................................................................................................................................9

6.1 

Commentary on maintenance of lifting stations in accordance with EN 12056

 ...................................... 9

6.2 

General maintenance hints .....................................................................................................................9

ABS lifting station Nirolift & Sanisett

Summary of Contents for Sanisett

Page 1: ...www absgroup com ABS lifting station Nirolift ABS lifting station Sanisett 1060 00 15975190GB 03 2006 Installation and Operating Instructions GB...

Page 2: ...5 1 4 Description 5 2 Safety 5 3 Transport 5 4 Set up and Installation 6 4 1 Installation of the collection tank 6 4 2 Installation of the submersible pump 6 4 3 Opening of the collection tank inlet p...

Page 3: ...pumping of wastewater and sewage in accordance with DIN EN 12056 from locations and areas below the backwash level m These lifting stations may not be used for the collection or pumping of flammable...

Page 4: ...Nirolift Sanisett 1062 00 Figure 2 Sanisett installation example and dimensions 1063 00 1064 00 Figure 3 Opening connection ports Figure 4 Sanisett float switch installation 1065 00 1066 00 Figure 5...

Page 5: ...ng stations of the Nirolift Sanisett consist of a synthetic collection tank which is waterproof in according with DIN EN 12050 2 together with a cover plate with odour preventing filter and lockable f...

Page 6: ...for reasons of the progress of construction work it is impossible to install the venting and pressure pipes before pouring of the concrete one has to use a polystyrene core between the tank and the in...

Page 7: ...g Insert the white plastic installation cover into the frame of the upper fitting The cover is only suitable for foot traffic See Figure 5 Adjust the upper fitting in the tank opening until the edge o...

Page 8: ...oles are accessible after unscrewing the lower housing cover ATTENTION Do not drill through the housing of the control unit itself NOTE A number of different control box models exist Please check the...

Page 9: ...al premises every three months in apartment blocks every six months in a single family home once a year In addition we recommend that a maintenance contract be taken out with a qualified company 6 2 G...

Page 10: ...ABS Production Wexford Ltd Clonard Road Wexford Ireland Tel 353 53 91 63 200 Fax 353 53 91 42335 www absgroup com...