 Part number 20068, Rev 0 

 

Programming Mode 

Note: The programming mode gives access to several functions that are 

not intended for user adjustment. The procedures below provide 

direction to the functions that you can adjust. Please do not attempt to 

change any of the other functions in the programming area or your unit 

may be damaged or become unstable.    

 

Locking and Unlocking the Control 

The control keys can be locked out to prevent inadvertent operation.  

To lock the control keys, simultaneously press and hold the up arrow and the down 

arrow. The display will show “POF”.  At this point you can only use keys to view the SET 

temp and the minimum and maximum stored temperatures.  

 

To unlock the control keys, simultaneously press and hold the up arrow and the down 

arrow. The display will show “Pon”. The control keys are now unlocked and you can 

perform the programming functions below.  

 

Adjusting the temperature control set points: 

NOTE: The temperature control  set  points are preset at the factory to 

provide the desired air and product temperatures inside of the unit and 

require no further adjustment. Please contact the manufacturer’s 

Technical Service Department before making any adjustments to 

determine if adjustment is necessary and, if so, to make sure it is 

performed properly. 

 

 

 

-

 

To set the compressor off set point, press and hold the SET key for 2 seconds. The current 
value will be displayed and the C or F icon will flash. Use the up or down keys to change the 
value. Press SET again to lock in the value.

 

-

 

To set the compressor on set point, you will need to adjust the differential, or Hysteresis 
setting. This is the number of degrees the controller will allow temperature to drift up until 
it restarts the compressor. For example, if the SET point is 3 degrees Celsius and the 

Summary of Contents for ABT-UCBI-0404G

Page 1: ...livery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When concea...

Page 2: ...L SERVICE please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left OR ri...

Page 3: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Page 4: ...is cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VARY M...

Page 5: ...ecially if the weather is very hot This is normal The motor compressor will cycle normally as soon as the excess heat has been removed TEMPERATURE CONTROL NOTE The control is preset at the factory to...

Page 6: ...ides of the unit to allow for proper air flow and therefore more even cooling of the product When loading the top shelf avoid blocking the evaporator fan s if installed There should be at least 4 inch...

Page 7: ...ides the following functions Red LED for visual indication of an alarm condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a set point is attaine...

Page 8: ...Pon The control keys are now unlocked and you can perform the programming functions below Adjusting the temperature control set points NOTE The temperature control set points are preset at the factor...

Page 9: ...isplay Press the UP or DOWN keys several times to cycle through the parameters until CF is displayed Press SET to display the current setting either C for Celsius or F for Fahrenheit Use the UP or DOW...

Page 10: ...d the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by fros...

Page 11: ...bove 40C 104F Stop using immediately The display shows LL and the compressor does not run The ambient temperature is below 40C 40F Stop using immediately MOISTURE DURING THE SUMMER SEASON The amount o...

Page 12: ...e the proper tools When cleaning stainless steel surfaces take care to use non abrasive tools Soft cloths and plastic scouring pads will not harm the steel s passive layer Stainless steel pads may be...

Page 13: ...er Sheen Passive Film Breakdown Corrosion on metals is everywhere We recognize it quickly on iron and steel as unsightly yellow orange rust Such metals are called active because they actively corrode...

Page 14: ...e paid by the customer ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compr...

Page 15: ...t damage during transit or installation fire flood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with t...

Reviews: