 Part number 20068, Rev 0 

 

STARTING  

There are no compressor shipping bolts to loosen or valves to open.  All that is necessary after 
the unit has been properly leveled is to plug the service cord into an electrical outlet  When 
starting this new appliance, allow the cabinet to operate a minimum of four hours or until it has 
started cycling normally before placing product in the cabinet.  The motor compressor may 
start and stop several times when the unit is first started or after defrosting, especially if the 
weather is very hot.  This is normal.  The motor compressor will cycle normally as soon as the 
excess heat has been removed.    

 

TEMPERATURE CONTROL 
 

NOTE: The control is preset at the factory to provide the desired air and product 
temperatures inside of the unit and requires no further adjustment. Please 
contact the manufacturer’s  Technical Service Department  before making any 
adjustments to determine if adjustment is necessary and, if so, to make sure it is 
performed properly. 

 

This unit has an electronic temperature controller located on the front panel above the door. 
This  controller  controls the compressor. Operation of this controller is described starting on 
page 7 of this manual.  

 

 

 

Summary of Contents for ABT-UCBI-0404G

Page 1: ...livery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the unit is being unpacked When concea...

Page 2: ...L SERVICE please have the unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left OR ri...

Page 3: ...y receipt acknowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along wi...

Page 4: ...is cabinet must conform to all National and Local Electrical Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VARY M...

Page 5: ...ecially if the weather is very hot This is normal The motor compressor will cycle normally as soon as the excess heat has been removed TEMPERATURE CONTROL NOTE The control is preset at the factory to...

Page 6: ...ides of the unit to allow for proper air flow and therefore more even cooling of the product When loading the top shelf avoid blocking the evaporator fan s if installed There should be at least 4 inch...

Page 7: ...ides the following functions Red LED for visual indication of an alarm condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a set point is attaine...

Page 8: ...Pon The control keys are now unlocked and you can perform the programming functions below Adjusting the temperature control set points NOTE The temperature control set points are preset at the factor...

Page 9: ...isplay Press the UP or DOWN keys several times to cycle through the parameters until CF is displayed Press SET to display the current setting either C for Celsius or F for Fahrenheit Use the UP or DOW...

Page 10: ...d the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by fros...

Page 11: ...bove 40C 104F Stop using immediately The display shows LL and the compressor does not run The ambient temperature is below 40C 40F Stop using immediately MOISTURE DURING THE SUMMER SEASON The amount o...

Page 12: ...e the proper tools When cleaning stainless steel surfaces take care to use non abrasive tools Soft cloths and plastic scouring pads will not harm the steel s passive layer Stainless steel pads may be...

Page 13: ...er Sheen Passive Film Breakdown Corrosion on metals is everywhere We recognize it quickly on iron and steel as unsightly yellow orange rust Such metals are called active because they actively corrode...

Page 14: ...e paid by the customer ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compr...

Page 15: ...t damage during transit or installation fire flood or other external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with t...

Reviews: