background image

 

REFRIGERATOR AND FREEZER OPERATION

 

After the unit is properly installed and power is applied, it will take some time before the 
system is cooled down to temperature and cycling normally. You should wait 8 hours on the 
first startup before beginning to add product to the unit. This ensures that the unit is installed 
and operating properly before being put into service. On subsequent startups (after cleanings, 
for example), this wait time can be reduced to about 3 hours.   After this wait time, the unit 
should be cycling in the design temperature range. The units are calibrated before leaving the 
factory, so no adjustment should be necessary.  

Loading the units will again cause temperature to rise as the warmer product is introduced into 
the compartment. If a large amount of product is to be introduced, it is a good idea to do it in 
stages, allowing several hours between stages to allow temperature to stabilize again before 
introducing additional warm product. This will minimize the temperature transient while 
loading. Other tips for successful loading include:  

-

 

Leave about 2-3 inches of free space along the back and sides of the unit to allow for proper 
air flow and, therefore, more even cooling of the product.  

-

 

When loading the top shelf, avoid blocking the evaporator fan(s) (if installed). There should 
be at least 4 inches of clearance below the fan(s) to allow proper air flow.  

-

 

Do not overload the unit. A full load is about 70 to 75% full. Additionally, the load should be 
distributed evenly from top to bottom and side to side for best results.  

-

 

Minimize the time the door is open. On top of letting the cold air out, you are also letting 
warm, moist air in which can result in more condensation and/or frost in the unit.  

Remember that the units are calibrated to the design  temperature range before  leaving the 
factory. We also do extensive testing to ensure that these temperatures will result in product 
temperatures in the desired band. There should be no need to adjust the temperature control 
on these units, but if it is necessary, they can be adjusted using the manual thermostat on the 
back of the unit

.  

 

It is STRONGLY RECOMMENDED that you contact our Technical Support Department prior to 
performing any temperature adjustments to ensure the adjustment is necessary and, if so, it 
is performed correctly.

  

 

 

Summary of Contents for ABT-FC-30

Page 1: ...rrier s agent driver at time of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of damage may not be discovered until the...

Page 2: ...unit s model and serial number ready as well as the problem description The model and serial number is located on the serial tag which can be found on the interior left upper wall of the unit For con...

Page 3: ...STORING UNSEALED CONTAINERS OF CORROSIVE MATERIALS CAN CAUSE PERMANENT DAMAGE TO THIS REFRIGERATION UNIT AND WILL VOID THE WARRANTY ALWAYS WEAR SAFETY GLASSES WHEN WORKING WITH THIS EQUIPMENT ANY UNAU...

Page 4: ...knowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along with a formal...

Page 5: ...SHOULD NOT VARY MORE THAN 5 FROM SERIAL PLATE RATINGS A separate circuit is recommended to prevent possible loss of product due to over loading or failure of other equipment on the same circuit PROTE...

Page 6: ...rature control NOTE Temperature controls are preset at the factory to provide the desired air and product temperatures inside of the units and require no further adjustment Please contact us before ma...

Page 7: ...ng include Leave about 2 3 inches of free space along the back and sides of the unit to allow for proper air flow and therefore more even cooling of the product When loading the top shelf avoid blocki...

Page 8: ...re pushed against rear wall or interrupted the proper refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or...

Page 9: ...oor will not close The unit is not level Refer to the Leveling section at the beginning of this manual Check for dirt and debris or items passing through the door seal MOISTURE DURING THE SUMMER SEASO...

Page 10: ...ovable shelves in dishwasher Exterior and Handles Soap and water Non Abrasive Glass Cleaner Do not use commercial household cleaners ammonia or alcohol to clean handles Use a soft cloth to clean smoot...

Page 11: ...or drain Replace the drain plug when defrosting is complete so warm air does not enter the freezer through the hole Defrosting tips If the frost is soft remove it with a plastic scraper If the frost i...

Page 12: ...n to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed compressors to be free from defects in both material and workmanship under norma...

Page 13: ...external causes It does not apply to defects resulting from failure to properly install operate or maintain the product in accordance with the printed instructions provided or damage caused by the sto...

Reviews: