background image

www.absgroup.com

ABS lifting station Piranhamat

11

13-00

15970314GB (10/2006)

Installation and Operating Instructions

GB

Summary of Contents for 100

Page 1: ...www absgroup com ABS lifting station Piranhamat 1113 00 15970314GB 10 2006 Installation and Operating Instructions GB ...

Page 2: ...t 100 120 lifting unit 6 4 Set up and Installation of the Piranhamat 100 120 7 4 1 Installation inflow side 7 4 1 1 Installation discharge line 8 4 1 2 Venting 9 4 1 3 Connection of wash hand basin bidet or shower 9 4 2 Electrical Connection 9 5 Commissioning 10 6 Maintenance 10 6 1 Maintenance of the Piranhamat 100 120 lifting unit 10 6 2 General maintenance hints 10 6 3 Steps to be taken should ...

Page 3: ...pes of smaller diameter from DN 25 or through flexible hose It is important to note that the Piranhamat 100 120 is not a sanitary disposal unit although it may shred particular sanitary items dropped accidentally into the WC m The lifting unit may not be used for the collection or pumping of flammable liquids A maximum of one toilet one wash hand basin and one shower tray may be connected for norm...

Page 4: ...pean countries e g Germany specify a minimum inflow height of 180 mm for the connection port of additional effluent sources the connection at height 74 mm is not available on versions with the part no 07560310 07565091 If exchanging an older model and it is not possible to move the inflow pipe position then the version with part no 07560320 07565092 with the lower inflow height of 74 mm and the se...

Page 5: ...gle WC one wash hand basin one bidet and one shower tray may be connected The direct or indirect connection of other effluent sources is not allowed In addition another WC must be available above the sewer backwash level If more effluent sources are present then we recommend our series Sanimat ATTENTION The regulations of DIN 1986 100 EN 12050 and 12056 should be observed 1 4 Accessories The Piran...

Page 6: ...idet and a single shower tray Piranhamat 120 only The unit has a built in acoustic alarm signal that is activated when the water level remains at a high level for more than 30 seconds 3 1 Design of the Piranhamat 100 120 lifting unit 1106 00 Figure 4 Design of the Piranhamat 100 120 lifting unit Venting by means of carbon filter with the facility for connection of vent line Inflow deflector plate ...

Page 7: ...up cannot occur ATTENTION see note under 1 2 1 version with part no 07500320 07565092 4 1 Installation inflow side ATTENTION When installing the discharge line ensure that Section 5 1 1 Discharge line is observed The Piranhamat 100 120 1 is designed for a direct toilet connection The Piranhamat 100 120 unit is set up directly behind the toilet The sealing sleeve should be drawn up directly on to t...

Page 8: ...out of position 1 Piranhamat 100 120 1109 00 2 Cap 3 Discharge left 4 Discharge right 5 Discharge line connection valve Figure 6 Discharge line connection of Piranhamat 100 120 Install the discharge line outer diameter 25 or 32 mm with the aid of a backwash loop 180º bend and connect it into the sewer line above the sewer backwash level The flap type non return valve should be fitted direct to the...

Page 9: ...on part no 07560320 07565092 with the lower opening See note under 1 2 1 4 2 Electrical Connection c Before commissioning an expert should check that one of the necessary electrical protective devices is available Earthing neutral earth leakage circuit breakers etc must comply with the regulations of the local electricity supply authority and a qualified person should check that these are in perfe...

Page 10: ...kshop and where original ABS spare parts have been used 6 1 Maintenance of the Piranhamat 100 120 lifting unit We recommend that the lifting unit be inspected visually every month and its functioning checked In addition we recommend that a Maintenance Contract be concluded with a qualified specialist company USER TIP Switching the power supply to the unit OFF and ON will operate the unit manually ...

Page 11: ...g the rotorshaft with a screwdriver or electrical drill Withdraw the deflector plate 9 3 upwards out of the tank and clean the tank m There is a danger of injury from the cutting tool in the hydraulic system Do not place your hand in the tank when the rotorshaft is being turned in accordance with Fig 10 with a screwdriver or drill Replace the deflector plate 9 3 back in the tank Screw back in plug...

Page 12: ...riod the Piranhamat 100 120 does not function correctly then withdraw the plug and call the ABS service NOTE In the case of any queries it is essential that the pump type and part number are given 6 3 3 Changing the Carbon Filter NOTE Normally it is only necessary to change the filter if damage has occurred Press the latches 9 2 on the tank cover 9 1 lightly to the outside and lift off the tank co...

Page 13: ...he cover 9 1 Remove the float protection 9 6 Withdraw cap 9 7 from motorhousing Unscrew plugscrew 9 8 and clear a possible blockage of the cutting system by rotating the rotorshaft with a screwdriver 10 1 Finally fit a drill with screwdriver attachment 10 2 NOTE By driving the rotorshaft with an electric drill the hydraulic system of the Piranhamat 100 120 will be operated and the tank emptied Swi...

Page 14: ...14 Installation and Operating Instructions ABS lifting station Piranhamat ...

Page 15: ...tion Piranhamat 100 120 GB To which this declaration relates are in conformity with the following standards or other normative documents DE Auf die sich diese Erklärung bezieht den folgenden und oder anderen normativen Dokumenten entsprechen FR Auxquels se réfère cette déclaration sont conformes aux normes ou à d autres documents normatifs ES Objeto de esta declaración están conformes con las sigu...

Page 16: ...ABS Production Wexford Ltd Clonard Road Wexford Ireland Tel 353 53 91 63 200 Fax 353 53 91 42335 www absgroup com ...

Reviews: