PANEL HANDBOOK aH72 SK
V 6.0
11
/ 31
Fig. 3.
Detail of the distances between triangle anchors depending on the inclination
3.1.4
Panel rails
The panel rails, upper and lower, are formed by joining the 50x85 profiles using the connecting strips
supplied in the accessories set. The profiles are supplied in different sizes depending on the number of
panels to be installed per row and, therefore, the final length of the rails varies according to this figure.
Fig. 4.
Connecting strip for panel rails
The lower panel rail installation must have a distance of 1945mm from the upper panel rail, measured
between the inner faces of the rails. This will be anchored to the triangles by means of two pre-
assembled connecting clamps consisting of a clamp, a hammerhead screw and a flange nut. The flap of
the clamp must be on the lower edge of the 40x40 profile of the triangle, thus marking exactly the
separation between the upper and lower guides that will allow us to install the panels correctly.