Assembly/ Installation
The product is to be set up or installed at the inten-
ded use site under due consideration of the following
conditions:
• At the location and site all applicable provisions of
law must be clarified and compliance with them
assured.
• The ground and space relations are to be clarified
prior to set-up/installation of the product in order
to assure safe operation for the personnel and the
product long-term. The product must be set-up/
installed so that safe, permanent operation is
assured.
• The product may only be set up and commissioned
by specially trained technicians.
• The product is constructed for rooms that are
protected from the influence of the weather
(industry standard).
• The operation and storage in aggressive or humid
environments or outdoors can lead to corrosion
damages.
Commissioning
• Set the feed pump into an appropriate original
container with corresponding follower plate.
• Connect the feed pump to the compressed air
supply (Figure A/No. 8). ATTENTION: The pump
starts immediately after it is connected to the
compressed air supply.
• Bleed the feed pump (Figure A/No. 3) until grease
comes out continuously.
• Turn off the feed pump
disconnect or turn off the
compressed air supply (Figure A/No. 8).
Packing, Transport and Storage
The product will be prepared for transport to its first
destination by ABNOX. The packing unit may not be
subjected to any excess load. The packaging and
its content must be protected from moisture. The
transport temperature must be kept between – 20°C
and + 40°C.
Transport Damages
If transport damages are discovered during the
inspection of incoming goods, this procedure must
be followed:
• Inform delivering party (freight carrier, etc.)
• Make record of damages
• Inform supplier
Storage
Storage and temporary storage in aggressive or
humid environments or outdoors can lead to
corrosion and other damages. The storage
temperature must be kept from – 20 °C to +40°C.
Training of Personnel
Only trained and instructed personnel who have read
and understood all points of the Operating Manual
may work on the product. Likewise the individual
operating states must be mastered, and the related
safe aspects must be known and they must be able
to implement them. Personnel undergoing training
may only work on the product under the supervision
of qualified personnel.
Maintenance
The indicated maintenance intervals are based on
single-shift operation. Depending on the use site,
medium and cases of multi-shift operation, main-
tenance may need to be performed more frequently.
CAUTION
All work on the plant absolutely
must be done when it is idle. The
pneumatic and hydraulic systems
must be de-pressurised. The
manometers must show 0 bar.
WHEN
WHAT
HOW
WHO
Weekly
Check pump
for leak
tightness
Visual
Qualified
personnel
of the
operating
company
Monthly Clean pump
and inspect
for damage
Visual
Qualified
personnel
of the
operating
company
Annually Thoroughly
clean pump
and replace
seals if
necessary
ABNOX
seal kit
Qualified
personnel
of the
operating
company