9
ADJUSTMENT OF THE DOOR MOVEMENTS
Se S/A- Adj
Error
Adjustment
OK
OK
Adjust-
ment
Error
Control unit adjustments and selections
Control unit:
:
When the mains supply is connected, the control unit immediately adopts the status
determined by the program selector and the opening pulses. Only the green OK
LED is lit.
Press one of the three buttons and the display will show the status of the door
operator.
Display functions and program push
buttons:
The display
program selector
comprises of two digital
displays, three LED's and three push
buttons.
The left display section shows the status
of the
. When a
programme button is pressed, the digital
display lights up, indicating the status of
the program selector e.g. 0 = MANUAL,
1= AUTO or 2=OPEN.
The right-hand display section indicates
the status of opening pulses, the safety
sensor and the locking
circuit.
Signal LED's
a)
is lit when the mains supply
is connected to the door operator. The
normal operating status.
b)
is not normally lit. The adjustment
LED is on when control point 0...28 has been
selected using the sel button.
c)
when lit indicates an error
condition has occurred.
The green OK LED
The yellow LED
The red Error LED
E1 = safety sensor fault; check the sensor connections
E3 = button error; check the sequencing (jumpers and connections)
E5 = battery fault; check the battery
E8 = Eprom error; replace the control unit
safety sensor
pulse display
Program selector
status
locking circuit
impulse inside
impulse outside
impulse outside
inhibit
signal dot
S
_
A