Page 1: ...ABLOY DA400 Swing door operator PROGRAM VERSION 1 5 PICOMED...

Page 2: ...n operation Removal of housing Function switches Installation Electrical connections Adjusting door movements Control points Internal connections External connections Battery operation Battery adapter...

Page 3: ...tions ABLOY s extensive network of sales and after sales service points will ensure long and trouble free service life for the automatic swing door operator The automatic swing door operator has been...

Page 4: ...nd ULC Canada Fire door use Finland USA Canada Closing force must not exeed 178 N 40 lb for a pedestrian application Closing time for last 10 degrees must be at least 1 5 seconds UL requirement The fi...

Page 5: ...ises temperature range 10 50 C Stored in dry premises temperature range 30 85 C The automatic swing door operator must not be installed in applications where it is subjected to water or snow o o Techn...

Page 6: ...ses must be volts free N O Normally open All the functions of the control unit are determined by a microprocessor The functions of the automatic door operator e g opening and closing speed lock up for...

Page 7: ...or MANUAL the door will close after a preset delay AUTO OPEN I O AUTO OPEN Warning Disconnect mains supply when removing or mounting the housing Remove the housing by inserting a wide blade screw driv...

Page 8: ...n standard applications Maximum extension shaft length 60 mm Extension shafts 10 mm 20 mm 60 mm push function pull function Mount a door stop to the door open position so that wind will not drive the...

Page 9: ...are provided with wiring holes enabiling concealed wiring a Push function drilling diagrams use mounting plate DA100 frame depth max 150 mm with standard arm 7281 or DA140 and 150 250 mm with standar...

Page 10: ...cealed wiring b Pull function drilling diagrams use mounting plate DA100 use sliding arm 7611 or DA142 minimum door width for sliding arm application is 750 mm arm DA142 is also provided with inch mac...

Page 11: ...g pin This plug will only fit into a grounding type outlet If the plug does not fit into the outlet contact a qualified electrician to install the proper outlet Do not change the plug in any way Perma...

Page 12: ...one of which is open When the perimeter sensor locates the edge of the notch the door operator stops the door Adjusting the door closed position 1 Mount the operator and fit the arm When closing the...

Page 13: ...ay lights up indicating the status of the program selector e g 0 MANUAL 1 AUTO or 2 OPEN The right hand display section indicates the status of opening pulses the safety sensor and the locking circuit...

Page 14: ...has been selected with the Selection button pressing the Adjustment button validates the and flashes on the display The Adjustment LED will also flash except for a sealed control point disappears from...

Page 15: ...o Control value Description 3 60 3 60 0 60 1 10 0 15 1 10 1 10 0 60 1 10 1 10 1 10 0 10 Opening direction Starting point of final speed Door open position Closing direction Starting point of final spe...

Page 16: ...tory settings Sealed Battery operation Inside impulse Hold open time Operation of lock control relay Closing direction Safety feature Hold open force Pressure closed before opening Lock control relay...

Page 17: ...g to accommodate for the locks release Adjust the opening speed so that the safety feature is not activated Adjust the final speed in order so that the door stops at the open position Hold open time f...

Page 18: ...e operation in closing direction 0 the door stops 1 the door stops and reopens The hold open force drives the door for example to a door stop CONTROL POINTS The safety feature stops the door movement...

Page 19: ...y of the second door is adjusted in control point 4 Note The inside impulse connection is not operational 3 Interlock controlled doors Used in two door following each other The first door opens from i...

Page 20: ...ter indicates number of openings The fixed obsticles in safety sensor zone can be excluded by adjusting the area smaller than the door open position Dispalys the program version 0 DA400 Europe 1 DA400...

Page 21: ...d to minimum With hold open times the distance from impulse device to door is preset 1 Adjust low speeds 1 3 Control points 5 6 9 and 10 2 Adjust the sensitivity to maximum 10 Control point 8 3 Adjust...

Page 22: ...black Locking circuit Sequencing Motor Battery T 800mA Mains switch Remove connections when using separate program switch INTERNAL CONNECTIONS LN br bl Ground ye br re bl br 115V 230V Select the righ...

Page 23: ...0 mm Max 200 mm The power supply cord shall not be routed through doorways window openings walls ceilings floors or the like attached or otherwise secured to the building structure concealed behind wa...

Page 24: ...operator 2 Outside impulse inhibit Main power state EXTERNAL CONNECTIONS Only voltage free switches with a normally open output can be used to control the ABLOY automatic swing door operator Moreover...

Page 25: ...Contacts ratings Max power 0 8A 30V resistive 0 3A 30V inductive The relay reacts to an opening impulse The relay hold time adjustment refer to control point 22 8 The control unit provides 12 and 24...

Page 26: ...e battery operation ON If battery operation is not selected the battery will not be charged Battery test When the power is switched on the control unit tests the battery by loading it for a 30 second...

Page 27: ...after a preset delay control point 16 The operator will remain in low energy state To re enegise the operator a single manual opening is required following which it will revert to the selected progra...

Page 28: ...D stops blinking If the operator stays in low energy state one manual opening is required to re enegise the operator to chosen program selector mode When battery backup is chosen the battery is checke...

Page 29: ...noted Battery operation is set to 12V battery The battery is tested if the voltage rises above 26 V it is operational If the voltage does not rise above 26 V in 24 hour period the battery should be re...

Page 30: ...ailure and the battery alarm indicates if the battery voltage drops under 11 5V Battery alarm reset Push to reset the alarm on the adapter Battery alarm keep If the jumper is on the battery alarm stay...

Page 31: ...ttery alarm reset Push to reset the alarm on the adapter Battery alarm keep If the jumper is on the battery alarm stays on until the reset button is pressed otherwise there is no keep function Fire de...

Page 32: ...onnected from the Battery adapter connector 6 causing the operator to change to the MANUAL position regardless the position of the programming switch Also in case of the power failure the operator cha...

Page 33: ...l point and adjust value 3 Press Errors ERR 1 Wrong master code ERR 2 Communication error ERR 3 Value was not saved Factory settings press both buttons for 2 seconds until FCLr text diappears Settings...

Page 34: ...INWARD Door operator 1 inward traffic outer door opens first inner door s delay adjusted on door operator 2 Door operator 2 outward traffic inner door opens first outer door s delay adjusted on door...

Page 35: ...drive the door closed for 0 4 seconds allowing the latch freedom of movement ABLOY lead cover 8810 or 8811 should always be used for swing door situations ABLOY Electric lock 8380 solenoid lock case...

Page 36: ...811 should always be used for swing door situations Motor locks 8120 8320 2 the impulse device opens both the lock and the door ABLOY lead cover 8810 or 8811 should always be used for swing door situa...

Page 37: ...evice opens both the lock and the door the door operator receives the locking circuit information from the microswitch in the lock case ABLOY lead cover 8810 or 8811 should always be used for swing do...