Fig 60. TCP Client mode in link mode
6.4.3. UDP for Link Mode
Operation: [Main]
Æ
[4 Serial Settings]
Æ
[1 Link mode]
Æ
[3 UDP]
SW5001 can be configured to work in UDP mode to establish connection using
Unicast
or
Multicas
t
protocol. Data can be transmitted from one or multiple serial devices to/from one or multiple host PCs and
vice versa. For example, the original RS-422/ RS485 bus data is transferred over the extended connected
distance by SW5001s, The destination IP is assigned by single IP or group IPs, The configuration is limited
by the Local Listening Port, default 4660 on the COM1 port of SW5001.
SW5001 can support up to 4-group IPs for UDP connection, if users needed.
Fig 61. UDP mode in link mode
Note: In this phase, UDP mode does not support Virtual COM mode.