Assembly
6
Mounting height (Fig. D)
A
mounting height of 150 cm is recommended for a 3-m charging cable.
Electrical connection (Fig. E)
WARNING!
Before operating, installing or opening the charging station, read and ob-
serve the safety information provided. Switch off the power before ope-
ning the device, and ensure it cannot be switched back on.
Only trained personnel may connect the charging station to the building’s supply grid
and put the device into operation. Any applicable national standards and regulations
must be observed.
The power supply of the charging station must be protected by a circuit breaker (MCB)
whose nominal current exceeds neither the maximum charging current of the charging
station nor the maximum capacity of the supply cable itself.
Connect the power supply to the connectors on the charging station marked L1 and N
on the RCCB. The earth conductor (PE) is connected to the earth conductor terminal on
the mounting rail.