background image

    

  

4) Cartridge tracking force adjustment

4-a) Ensure that the tracking force adjustment knob is set to the zero position.
4-b) With the cartridge permanently fitted in the correct position adjust the counter weight so that

the   arm   is   floating   with   the   stylus   approx.   3mm   –   5mm   clear   of   a   vinyl   record.   (This
adjustment should be made with the anti-skating knob to zero.)

4-c) Rotate the counter weight and move forward. Each graduation is equivalent to 0.25 grams

tracking force.

* The applied range of weight of headshell with cartridge is from 15grams - 29grams (including 

headshell).

 

5) Anti-Skating (bias) adjustment

5-a) Set the bias adjustment knob to the same number as the required tracking force.

                 

Custom made in Japan for:

Sibatech, Tokyo, Japan.

Tracking force ring

Counter weight

Reviews: