EN - 3
MAG
1 Designated Use
1 Designated Use
The MAG hand operated welding torches are used in industry and in the trade
for welding using active gases (MAG). They consist of the torch neck with
equipment parts and wearing parts, handle and cable assembly with central
connector. They correspond to EN 60 974-7 and are not considered to be
devices having their own functions. Arc welding can only be carried out in
connection with a welding power supply.
2 Technical Data
For pulse arcs, the load data are reduced by up to 30 %.
Ambient temperature of welding
- 10 °C to + 40°C
Transport and storage
- 25 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Temperature
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Type of use
Hand-held
automatic
Wire types
commercially available round wires
Shielding gas
(DIN EN ISO 14175)
CO
2
and M21
Voltage rating
113 V peak value
141 V peak value
Protection type of the machine
side connections (EN 60 529)
IP3X
IP2X
Tab. 2
General torch data (EN 60 974-7)
Type
Type of
cooling
Load
ED
Wire
Gas flow
Cooling
Flow
pressure
CO
2
M21
Max. supply
temp.
Min.
flow
min.
max.
A
A
%
mm
l/min
°C
l/min
bar
bar
RBC 61GD
air
350 320 35
1.0 - 2.0 10 - 20
RB 610D
liquid
650 500 100 1.6 - 3.2 10 - 20
40
1.3
2.5
3.5
Tab. 3
Product-specific torch data (EN 60 974-7)