BAL.0140 • 2018-10-15
EN - 13
PP Plus 36D/240D/401D
4 Putting into operation
4.8 Setting the shielding gas
4.9 Feeding in the wire
NOTICE
• The type and quantity of the shielding gas depends on the welding task and the gas
nozzle geometry.
• Make all shielding gas connections gas-tight.
• To prevent the shielding gas supply from becoming clogged by impurities, the cylinder
valve must be opened briefly, before connecting the cylinder. This will blow out any
impurities that may be present.
CAUTION
Risk of injury
Puncture or cut-in wounds may be caused by the wire electrode.
• Keep your hands out of the danger zone.
• Wear the correct protective gloves.
1
Housing cover
2
Knurled screw
3
Clamp clip
4
Pressure adjustment screw
5
Wire feed roll support
6
Wire feed roll
7
Seat
Fig. 7
Feeding in the wire
1
2
3
4
5
6
7