BAL.0140 • 2018-10-15
EN - 5
PP Plus 36D/240D/401D
3 Product description
*For pulse arc welding, the load data are reduced by up to 35%.
3.2 Signs and symbols used
In the operating instructions, the following signs and symbols are used:
Type
Type of
cooling
Load*
Duty
cycle
Wire ø
Gas flow rate Cooling data
Flow
temp.
Flow
Flow pressure
CO
2
M21
max.
min.
min.
max.
PP Plus
A
A
%
mm
l/min
°C
l/min
bar
bar
36D
air
300
270
60
0.8 - 1.2 10 - 20
240D
liquid
270
240
100
0.8 - 1.2 10 - 20
50
1
1.5
3.5
401D
liquid
400
350
100
0.8 - 1.6 10 - 20
50
1
1.5
3.5
Tab. 3
Product-specific torch data as laid out in EN 60974-7 PP Plus
Standard length L (m)
8.00
Cooling unit power
min. 800 W
Control lead
7-wire
Weight/meter
approx. 0.7 kg
Machine-side connections
Central connector WZ-2 (liquid-cooled),
central connector KZ-2 (air-cooled)
Tab. 4
Cable assembly
Size
Groove
0.8 / 0.8 mm
U
1.0 / 1.0 mm
U
1.2 / 1.2 mm
U
1.6 / 1.6 mm
U
Tab. 5
Wire feed rolls
Symbol
Description
•
List of symbols for action commands and enumerations
Cross reference symbol refers to detailed, supplementary or further information
1