EN - 12
8 Putting out of operation
MIG/MAG ROBO welding torch
7.1 Welding process
1
Open the shielding gas cylinder.
2
Switch on the power source.
8 Putting out of operation
1
Wait until the shielding gas post-flow time has expired.
2
Close the shut-off valve for the gas supply.
3
Switch off the power source.
DANGER
Risk of burns
During welding sparks, glowing workpieces or hot slag can produce flames.
• Check the work area for flashpoints.
• Provide suitable fire extinguishing equipment at the workstation.
• Allow workpieces to cool down after welding.
• Prior to performing welding work, properly fasten the ground clamp to the workpiece or
the welding table.
WARNING
Arc eye
The arc produced by welding can damage the eyes.
• Wear protective clothing and eye protection.
NOTICE
• The device may only be operated by qualified personnel (in Germany see TRBS 1203).
• Never pull the cable assembly across sharp edges or place it in the welding spatter area
or on hot workpieces.
• Ensure that all required parameters, for example welding current, wire feed, etc., have
been set at the welding power source according to your welding task.
NOTICE
• When putting the system out of operation, ensure that the procedures for switching off all
the welding system components are observed.