EN - 9
Gouging torch
8 Putting out of operation
Before igniting the plasma arc, please observe the following:
1
Switch on the cutting current.
2
Open the compressed air valve.
3
Ignite the plasma arc by briefly touching the carbon electrode with the
workpiece and slide the carbon electrode back a little.
4
Keep the plasma arc length extremely small and pass the carbon electrode
evenly over the workpiece.
The compressed air jet usually follows this and air-blasts the melt.
8 Putting out of operation
To put the gouging torch out of operation, proceed as follows:
1
Pull back the carbon electrode.
2
Close the compressed air valve.
3
Switch off the power source.
9 Maintenance and cleaning
Regular cleaning, however, is a prerequisite for a long life and a trouble-free
operation.
WARNING
High sound level
The sound level of 105 to 118 dB is above the permissible limit value.
• Wear ear protection.
NOTICE
• The device may only be operated by qualified personnel (in Germany
see TRBS 1203).
• Clamping length of the carbon electrode to the plasma arc approx.
150 mm.
• Please also consult the operating instructions for the welding
components, such as power source, compressed air line.
NOTICE
• Please also consult the operating instructions for the welding
components, such as power source, compressed air line.
Summary of Contents for K10