19
FreedomDrive
8
Maintenance and cleaning
!
DANGER
Risk of injury due to unexpected start-up.
For the entire duration of maintenance, servicing, dismounting and repair
work, the following instructions must be adhered to:
• Switch off the power supply.
• Close off the compressed gas supply.
• Pull the mains plug.
!
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Switch off the power supply.
• Check all live cables and connections for proper installation.
• Replace any damaged, deformed or worn parts.
Note
•
Maintenance and cleaning work may only be carried out by qualified
and trained specialists.
•
Check coolant hoses, seals and connections for damage and tightness
and replace them, if necessary.
•
Always wear your personal protective clothing when performing
maintenance and cleaning work.
7
Putting out operation
Note
•
Liquid-cooled hose assemblies will start leaking if overheated. This is
why the cooling unit should continue running for approx. 5 min. after
welding.
1. Stop welding.
2. Wait until the shielding gas flow has subsided and then switch off the power
supply.
3. Close the valve of the shielding gas cylinder.
Summary of Contents for FreedomDrive Abimig AT355