EN
-
26
11 Disassembly
FEC
11 Disassembly
1
Remove the current clamp from the cable assembly.
2
Remove the extraction hose(s).
► Have the extraction system
checked by a qualified
electrician, replace if
necessary and press the motor
protective switch back in.
Dust escapes during filter
cleaning.
Exhaust air filter is
contaminated/defective.
► Replace the exhaust air filter.
9.4.2 Replacing the
exhaust air filter on
page EN
<0/Error> LED:
8× short flashes.
Error message: motor runtime
> 8 hours
► Switch off the device and
allow to cool.
<0/Error> LED:
3× short, 1× long,
4× short flashes.
Error message:
excess temperature
> 60 °C
► Switch off the device and
allow to cool.
<Dirty> LED is illuminated.
Filter elements saturated.
► Clean the filter.
9.2 Cleaning the filter on
page EN
Tab. 3
Faults and troubleshooting
Fault
Cause
Troubleshooting
WARNING
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. It can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Use the device only in rooms with forced ventilation.
CAUTION
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running
unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.
Summary of Contents for FEC