FEC W3
9 Maintenance and cleaning
BAL.0675.0 • 2019-09-16
EN - 19
9 Maintenance and cleaning
Regular ongoing maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
9.1 Maintenance intervals
The extraction system must be cleaned and inspected by qualified personnel as part of maintenance. Any dirty parts that
cannot be cleaned adequately must be replaced. These dirty parts must be placed in bags that are impermeable (so dust
cannot escape) and disposed of in accordance with regulatory stipulations.
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the
FEC W3
extraction system.
• Close off the compressed air supply.
• Disconnect all electrical connections.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Suitable safety measures must be taken before performing maintenance and cleaning work.
• Maintenance and cleaning work must only be carried out on the extraction system in areas with locally filtered forced
ventilation.
• Only qualified personnel are permitted to perform work on the device or system.
• Check and wear your personal protective equipment.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves and safety shoes.
NOTICE
• The specified maintenance intervals are standard values and refer to single-shift operation.
• We recommend recording the inspections. The date of the inspection, the detected defects and the name of the
inspector must be recorded.
Summary of Contents for FEC W3
Page 31: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 31 Abb 18 Elektroschaltplan 230 V 50 Hz...
Page 32: ...DE 32 BAL 0675 0 2019 09 16 13 Anhang FEC W3 Abb 19 Elektroschaltplan 120 V 50 60 Hz...
Page 33: ...FEC W3 13 Anhang BAL 0675 0 2019 09 16 DE 33 Abb 20 Elektroschaltplan 120 V 50 60 Hz...
Page 63: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 31 Fig 18 Circuit diagram 230 V 50 Hz...
Page 64: ...EN 32 BAL 0675 0 2019 09 16 13 Appendix FEC W3 Fig 19 Circuit diagram 120 V 50 60 Hz...
Page 65: ...FEC W3 13 Appendix BAL 0675 0 2019 09 16 EN 33 Fig 20 Circuit diagram 120 V 50 60 Hz...
Page 95: ...FEC W3 13 Annexe BAL 0675 0 2019 09 16 FR 31 Fig 18 Sch ma de connexion lectrique 230 V 50 Hz...